Comparison of the effects of kilohertz- and low-frequency electric stimulations: A systematic review with meta-analysis

PLoS One. 2018 Apr 24;13(4):e0195236. doi: 10.1371/journal.pone.0195236. eCollection 2018.

Abstract

Objective: This study aimed to determine whether kilohertz-frequency alternating current (KFAC) is superior to low-frequency pulsed current (PC) in increasing muscle-evoked torque and lessening discomfort.

Data sources: The electronic databases PubMed, PEDro, CINAHL, and CENTRAL were searched for related articles, published before August 2017. Furthermore, citation search was performed on the original record using Web of Science.

Review methods: Randomized controlled trials, quasi-experimental studies, and within-subject repeated studies evaluating and comparing KFAC and PC treatments were included. The pooled standardized mean differences (SMDs) of KFAC and PC treatments, with 95% confidence intervals (CIs), were calculated using the random effects model.

Results: In total, 1148 potentially relevant articles were selected, of which 14 articles with within-subject repeated designs (271 participants, mean age: 26.4 years) met the inclusion criteria. KFAC did not significantly increase muscle-evoked torque, compared to PC (pooled SMD: -0.25; 95% CI: -0.53, 0.06; P = 0.120). KFAC had comparable discomfort compared to that experienced using PC (pooled SMD: -0.06; 95% CI: -0.50, 0.38; P = 0.800). These estimates of the effects had a high risk of bias, as assessed using the Downs and Black scale, and were highly heterogeneous studies.

Conclusions: This meta-analysis does not establish that KFAC is superior to PC in increasing muscle-evoked torque and lessening discomfort level. However, no strong conclusion could be drawn because of a high risk of bias and a large amount of heterogeneity. High quality studies comparing the efficacy between PC and KFAC treatments with consideration of potential confounders is warranted to facilitate the development of effective treatment.

Publication types

  • Comparative Study
  • Meta-Analysis
  • Research Support, Non-U.S. Gov't
  • Review
  • Systematic Review

MeSH terms

  • Electric Stimulation / methods*
  • Electric Stimulation Therapy / methods*
  • Humans
  • Muscle Strength* / physiology
  • Muscle, Skeletal / physiology*
  • Torque

Grants and funding

This study was supported in part by a Grant-in-Aid from the Japan Society for the Promotion of Science (https://www.jsps.go.jp/) Research Fellows to HI. There was no additional external funding received for this study. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.