Design of a nitrogen purification system with cryogenic method for neutrino detection

Appl Radiat Isot. 2018 Jul:137:194-198. doi: 10.1016/j.apradiso.2018.04.009. Epub 2018 Apr 4.

Abstract

In order to detect the neutrino with liquid scintillation detector, high-purity nitrogen is essential for gas stripping in this detector. Therefore, it is necessary to design a purification system for the detector to purify nitrogen. Using the method of low temperature adsorption for the purification system, the key designs including the flow path, the adsorber and the selection of activated carbon, are introduced in this study. In these designs, the selection of activated carbon is the most important because the adsorption characteristic of the carbon is related to the performance of the purification system. The method of grand canonical ensemble Monte Carlo is adopted to simulate the adsorption of radon by the activated carbon with its slit pore model. Using this method, the working temperature and the key characteristic of the activated carbon are obtained.

Keywords: Cryogenic; Liquid scintillator; Monte Carlo; Nitrogen; Purification system.