Graphene-amplified femtosensitive aptasensing of estradiol, an endocrine disruptor

Analyst. 2018 Apr 16;143(8):1835-1845. doi: 10.1039/c7an02092a.

Abstract

We report the construction of a novel electrochemical femtomolar aptasensing APT-ERGO/GCE interface based on the covalent immobilization of 38-mer amine-functionalized (NH2-APT) 17β-estradiol (E2) DNA aptamers on a graphene amplifying platform. Graphene oxide (GO) was synthesized and characterized by using FTIR, UV-vis spectroscopy, XRD spectroscopy, and SEM technique. The strategy for the construction of the E2-aptasensing interface involves in a three-step modification process. (i) First, we carried out the electrochemical reduction of GO on the GCE electrode to form ERGO/GCE. (ii) Then, as an impact strategy, the E2-aptamers (NH2-APT) were further immobilized on the surface of the ERGO/GCE interface through electrochemical reduction of surface-functionalized diazonium salts. This step includes electrografting of ERGO/GCE by electrochemical reduction of the diazonium salt (ClN2+-Ph-COOH) to obtain the ERGO/GCE-Ph-COOH-modified electrode. (iii) Finally, the free carboxyl groups on the ERGO/GCE-Ph-COOH surface were conjugated with NH2-APT through formation of carbodiimide to afford an aptasensing APT-ERGO/GCE interface. The presence of ERGO as an amplifying platform led to the successful immobilization of E2-aptamers with a surface coverage of 1.9 × 1013 molecule per cm2, which is higher than the values obtained in other reported methods. The constructed aptasensing APT-ERGO/GCE interface was appraised using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The synergetic effect of high affinity and specificity of E2-aptamers and graphene platform was beneficial for the novel femtosensitive label-free electrochemical aptasensing APT-ERGO/GCE interface for the detection of [E2]. The oxidation current peaks at the aptasensing APT-ERGO/GCE interface were proportional to [E2] over two different concentration linearity ranges 1.0 × 10-15 mol L-1-9.0 × 10-12 mol L-1-1.2 × 10-11 mol L-1 to 2.3 × 10-10 mol L-1 with a limit of detection (LOD) of 0.5 × 10-15 mol L-1. This aptasensing APT-ERGO/GCE interface was employed as a femtomolar tool for the determination of [E2] in the environmental and pharmaceutical samples such as wastewater (spiked) and pharmaceutical dosages.

MeSH terms

  • Aptamers, Nucleotide*
  • Electrochemical Techniques*
  • Electrodes
  • Endocrine Disruptors / analysis*
  • Estradiol / analysis*
  • Graphite*
  • Immobilized Nucleic Acids

Substances

  • Aptamers, Nucleotide
  • Endocrine Disruptors
  • Immobilized Nucleic Acids
  • Estradiol
  • Graphite