Quantitative analysis of near-implant magnesium accumulation for a Si-containing coated AZ31 cage from a goat cervical spine fusion model

BMC Musculoskelet Disord. 2018 Apr 4;19(1):105. doi: 10.1186/s12891-018-2027-5.

Abstract

Background: Magnesium (Mg) released from Mg-based implants degradation is believed to be effective in improving osteogenesis, however, studies focusing on Mg-based interbody cages are limited and fusion success was never reported. As excessive Mg accumulation can inhibit new bone formation, this study is designed to explain the possible reasons for the fusion failure of Mg-based cages by analyzing the relationships between the intervertebral Mg accumulation and the resulting interbody fusion.

Methods: The experimental cage was consisted of magnesium alloy (AZ31) substrate and Silicon (Si) -containing coating. C3/C4 and C5/C6 of 24 goats were implanted with cage or autologous iliac crest bone graft (Control group), which were analyzed at 3, 6, 12, and 24 weeks post-operatively. Intervertebral Mg concentrations, Mg-related Calcium (Ca)/ Phosphorus (P) ratios, radiological evaluations and histological findings were recorded for analyzing the relationships between the three of cage corrosion, Mg accumulation, and interbody fusion.

Results: Intervertebral Mg levels were significantly increased after cage implantation, especially in the areas that were closer to the cages at 3 weeks post-operatively, and these increased concentrations could persist up to 12 weeks post-operatively, indicating a relatively rapid corrosion process. Significantly lower Mg levels were only found at 24 weeks post-operatively, but these levels were still higher than those of the control group. In addition, Mg was found to be widely distributed at the intervertebral space since high Mg concentrations could even be detected at the posterior boundary of the vertebral body. Under this Mg accumulation profile, interbody fusion was not achieved, as indicated by the decreased Ca/P ratios, low CT fusion scores and negative histological results.

Conclusions: Intervertebral excessive Mg accumulation might be the primary reason for interbody fusion failure. Quantitative Mg analysis can offer insight into the association between cage degeneration and biological response.

Keywords: Degradation; Histological concentration; Interbody cage; Magnesium; Quantitative analysis.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Absorbable Implants*
  • Animals
  • Calcium / metabolism
  • Cervical Vertebrae / diagnostic imaging
  • Cervical Vertebrae / metabolism
  • Cervical Vertebrae / pathology
  • Cervical Vertebrae / surgery*
  • Female
  • Goats
  • Magnesium / metabolism*
  • Male
  • Models, Animal
  • Osteogenesis*
  • Phosphorus / metabolism
  • Radiography
  • Spinal Fusion / instrumentation*

Substances

  • Phosphorus
  • Magnesium
  • Calcium