On-pump transapical cardioscopic mitral valve replacement with cardiac arrest: short-term results in a porcine survival model

Interact Cardiovasc Thorac Surg. 2018 Sep 1;27(3):437-445. doi: 10.1093/icvts/ivy076.

Abstract

Objectives: Favourable outcomes with mitral annuloplasty have been achieved with transapical cardioscopic (TAC) surgery in a survival animal model. In addition, experimental TAC on a non-survival animal model also showed adequate access to remove the native mitral valve and implant a prosthetic valve, but the surgical procedure took a long time and lacked follow-up data. The goal of this study was to develop a clinically translatable TAC mitral valve replacement (MVR) procedure using technical and instrumental refinements to reduce the surgical time and to evaluate functional recovery and short-term durability using a survival porcine model. We hypothesized that MVR could be achieved with subannular implantation of the bioprosthesis via the TAC approach.

Methods: TAC MVR using the Hancock II™ (Medtronic)® mitral prosthesis was performed in 6 pigs via an incision over the xiphoid process, under cardiopulmonary bypass and cardiac arrest. COR-KNOT® and minimally invasive cardiac surgery instruments were used. Haemodynamics, echocardiography, cardiac computed tomography, ventriculography and electrocardiography were used to evaluate the function of the mitral prosthesis and left ventricle, coronary system and conduction system in the perioperative period and 4 weeks later.

Results: A postimplant examination showed that the mitral prosthesis was competent, without a paravalvular leak. The left ventricular ejection fraction was comparable to preoperative values (65.2 ± 4.1 vs 67.2 ± 7.9). The bypass, cross-clamp and implant times were 177.2 ± 44.2 min, 135.3 ± 47.6 min and 94.0 ± 41.2 min, respectively. The prosthesis was in a good position. The apical scar was intact and not aneurysmal 4 weeks after the implant. The valve was properly sutured to the annulus, without a postimplant paravalvular leak. All animals recovered after 1 month of follow-up with preserved ventricular function and normal wall motion.

Conclusions: We successfully managed to replace the mitral valve with a biological prosthesis via the apex with encouraging bypass and cross-clamp times. This technique may provide an alternative for a selected group of patients with diseased mitral valves who have indications for MVR and still in a high-risk redo setting with conventional sternotomy or minimally invasive cardiac surgery-MVR.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Bioprosthesis*
  • Cardiopulmonary Bypass*
  • Echocardiography
  • Electrocardiography
  • Female
  • Heart Arrest, Induced*
  • Heart Valve Prosthesis Implantation / methods*
  • Heart Valve Prosthesis*
  • Hemodynamics
  • Minimally Invasive Surgical Procedures
  • Mitral Valve / surgery*
  • Models, Animal
  • Swine
  • Ventricular Function, Left