Performance of loop-mediated isothermal amplification assay in the diagnosis of pulmonary tuberculosis in a high prevalence TB/HIV rural setting in Uganda

BMC Infect Dis. 2018 Feb 21;18(1):87. doi: 10.1186/s12879-018-2992-1.

Abstract

Background: Smear microscopy lacks sensitivity especially in HIV co-infection, resulting in undiagnosed tuberculosis (TB) and high mortality. The loop-mediated isothermal amplification (TB-LAMP) assay can be staged with minimal infrastructure, is rapid, low cost and detection can be with the naked eye. We assessed feasibility and performance of Eiken TB-LAMP test at point-of-need in TB diagnosis in a high prevalence TB/HIV rural setting in Uganda.

Methods: From October 2013-February 2014, TB-LAMP testing was performed on sputum specimens from outpatient presumptive TB adults at a district hospital and two low-level health centers in Kiboga District where smear microscopy is the available routine diagnostic option. TB-LAMP was performed by a technician after a week of training in the district hospital. The technician had no prior experience in the technology. Samples from the low-level health centers were transported to the district hospital for TB-LAMP.

Results: Of the 233 presumptive TB (126 at hospital); 113 (48.5%) were HIV-infected; 129 (55%) male; median age 40 (IQR 30-53). Compared to MTB culture, overall sensitivity and specificity of TB-LAMP were 55.4% (95 CI 44.1-66.3) and 98.0% (95 CI 94.3-99.6) respectively. Among HIV-infected participants, TB-LAMP sensitivity and specificity were 52.3% (95 CI 36.7-67.5%) and 97.1% (95 CI 89.9-99.6) respectively; and 24.4% (95% CI 12.9-39.5) and 98.6% (95% CI 95.1-99.8) respectively among smear-negatives. TB-LAMP sensitivity and specificity were 62.2% (95% CI 44.8-77.5) and 97.8% (95% CI 92.1-99.7) in the hospital setting where central testing occurred compared to 50.0% (95% CI 34.9-65.1) and 98.4% (95% CI 91.2-100) respectively in low-level health centers where specimens were transported centrally.

Conclusions: In this high prevalence TB/HIV rural setting, TB-LAMP performs better than conventional smear microscopy in diagnosis of MTB among presumptive TB patients although the sensitivity is lower than that reported by the World Health Organization. TB-LAMP can easily be performed following a short training period and in absence of sophisticated infrastructure and expertise.

Keywords: Diagnostic; LAMP; Microscopy; Rural; Tuberculosis; Uganda.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Bacteriological Techniques
  • Female
  • HIV Infections / complications
  • HIV Infections / diagnosis*
  • Humans
  • Male
  • Middle Aged
  • Mycobacterium tuberculosis / genetics*
  • Mycobacterium tuberculosis / isolation & purification
  • Nucleic Acid Amplification Techniques
  • Prevalence
  • Rural Population
  • Sensitivity and Specificity
  • Sputum / microbiology
  • Tuberculosis, Pulmonary / complications
  • Tuberculosis, Pulmonary / diagnosis*
  • Tuberculosis, Pulmonary / epidemiology
  • Tuberculosis, Pulmonary / microbiology
  • Uganda / epidemiology