Diagnostic Performance of Measurement of Fecal Elastase-1 in Detection of Exocrine Pancreatic Insufficiency: Systematic Review and Meta-analysis

Clin Gastroenterol Hepatol. 2018 Aug;16(8):1220-1228.e4. doi: 10.1016/j.cgh.2018.01.027. Epub 2018 Jan 31.

Abstract

Background & aims: Tests to quantify fecal levels of chymotrypsin like elastase family member 3 (CELA3 or elastase-1) in feces are widely used to identify patients with exocrine pancreatic insufficiency (EPI). However, the diagnostic accuracy of this test, an ELISA, is not clear. We performed a systematic review and meta-analysis to determine the accuracy of measurement of fecal elastase-1 in detection of EPI.

Methods: We searched PubMed, Embase, and reference lists for articles through November 2016 describing studies that compared fecal level of elastase-1 with results from a reference standard, direct method (secretin stimulation test), or indirect method (measurement of fecal fat) for detection of EPI. Sensitivity and specificity values were pooled statistically using bivariate diagnostic meta-analysis.

Results: We included total of 428 cases of EPI and 673 individuals without EPI (controls), from 14 studies, in the meta-analysis. The assay for elastase-1, compared to secretin stimulation test, identified patients with pancreatic insufficiency with a pooled sensitivity value of 0.77 (95% CI, 0.58-0.89) and specificity value of 0.88 (95% CI, 0.78-0.93). In an analysis of 345 cases of EPI and 312 controls, from 6 studies, the fecal elastase-1 assay identified patients with EPI with a pooled sensitivity value of 0.96 (95% CI, 0.79-0.99) and specificity value of 0.88 (95% CI, 0.59-0.97), compared to quantitative fecal fat estimation. In patients with low pre-test probability of EPI (5%), the fecal elastase-1 assay would have a false-negative rate of 1.1% and a false-positive rate of 11%, indicating a high yield in ruling out EPI but not in detection of EPI. In contrast, in patients with high pre-test probability of EPI (40%), approximately 10% of patients with EPI would be missed (false negatives).

Conclusions: In a systematic review and meta-analysis of studies that compared fecal level of elastase-1 for detection of EPI, we found that normal level of elastase-1 (above 200 mcg/g) can rule out EPI in patients with a low probability of this disorder (such as those with irritable bowel syndrome with diarrhea). However, in these patients, an abnormal level of elastase-1 (below 200 mcg/g) has a high false-positive rate.

Keywords: Enzyme; Exocrine Pancreatic Insufficiency; Pancreas; Proteolysis; Steatorrhea.

Publication types

  • Evaluation Study
  • Meta-Analysis
  • Research Support, N.I.H., Extramural
  • Systematic Review

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Child
  • Child, Preschool
  • Diagnostic Tests, Routine / methods*
  • Exocrine Pancreatic Insufficiency / diagnosis*
  • Feces / chemistry*
  • Female
  • Humans
  • Infant
  • Infant, Newborn
  • Male
  • Middle Aged
  • Pancreatic Elastase / analysis*
  • Sensitivity and Specificity
  • Young Adult

Substances

  • Pancreatic Elastase