Fabry-Perot Interferometric High-Temperature Sensing Up to 1200 °C Based on a Silica Glass Photonic Crystal Fiber

Sensors (Basel). 2018 Jan 18;18(1):273. doi: 10.3390/s18010273.

Abstract

A Fabry-Perot interferometric sensor for temperature measurement was fabricated based on a silica glass solid-core photonic crystal fiber with a central air-bore. By splicing a stub of photonic crystal fiber to a standard single-mode fiber, an intrinsic Fabry-Perot cavity was formed inside the photonic crystal fiber. Sensing experiment results show that the sensor can work stably for a consecutive 24 h under temperatures up to 1100 °C, and the short-term operation temperature can reach as high as 1200 °C (<30 min). In the measurement range of 300-1200 °C, the temperature sensitivity of the peak wavelength shift can reach as high as 15.61 pm/°C, with a linearity of 99.76%. The presented interferometric sensor is compact in size and possesses advantages such as an extended working range and high sensitivity, showing promising application prospects.

Keywords: Fabry-Perot interferometer; high temperature; optical fiber sensor; photonic crystal fiber.