Diagnostic accuracy of 18F-FDG PET or PET/CT for the characterization of adrenal masses: a systematic review and meta-analysis

Br J Radiol. 2018 Jun;91(1086):20170520. doi: 10.1259/bjr.20170520. Epub 2018 Feb 5.

Abstract

Objective: We aimed to explore the role of the diagnostic accuracy of 18F fluodeoxyglucose PET (18F-FDG PET) or PET/CT for characterization of adrenal lesions through a systematic review and meta-analysis.

Methods: The MEDLINE, EMBASE, and Cochrane Library database, from the earliest available date of indexing through 30 April 2017, were searched for studies evaluating the diagnostic performance of 18F-FDG PET or PET/CT for characterization of adrenal lesions. We determined the sensitivities and specificities across studies, calculated positive and negative likelihood ratios (LR + and LR-), and constructed summary receiver operating characteristic curves.

Results: Across 29 studies (2421 patients), the pooled sensitivity for 18F-FDG PET or PET/CT was 0.91 [95% CI (0.88-0.94)] with heterogeneity (χ2 = 141.8, p = 0.00) and a pooled specificity of 0.91 [95% CI (0.87-0.93)] with heterogeneity (χ2 = 113.7, p = 0.00). Likelihood ratio (LR) syntheses gave an overall positive likelihood ratio (LR+) of 9.9 [95% CI (7.1-13.7)] and negative likelihood ratio (LR-) of 0.09 [95% CI (0.07-0.13)]. The pooled diagnostic odds ratio was 105 [95% CI (63-176)]. In metaregression analysis, study design, publication year, study location (western vs others), interpretation criteria of PET or PET/CT images, quantification of PET or PET/CT [SUVmax (maximum standardized uptake value) vs SUV (standardized uptake value) ratio], patient group, and analysis method (patient-based vs lesion-based) were the sources of the study heterogeneity. However, in multivariate metaregression, no definite variable was the source of the study heterogeneity.

Conclusion: 18F-FDG PET or PET/CT demonstrated good sensitivity and specificity for the characterization of adrenal masses. At present, the literature regarding the use of 18F-FDG PET or PET/CT for the characterization of adrenal masses remains still limited; thus, further large multicenter studies would be necessary to substantiate the diagnostic accuracy of 18F-FDG PET or PET/CT characterization of adrenal masses. Advances in knowledge: 18F- FDG PET or PET/CT showed good sensitivity and specificity for the characterization of adrenal masses and could provide additional information for that purpose.

Publication types

  • Meta-Analysis
  • Review
  • Systematic Review

MeSH terms

  • Adenoma / diagnostic imaging*
  • Adrenal Gland Neoplasms / diagnostic imaging*
  • Fluorodeoxyglucose F18*
  • Humans
  • Positron Emission Tomography Computed Tomography*
  • Positron-Emission Tomography* / methods
  • Radiopharmaceuticals*
  • Sensitivity and Specificity

Substances

  • Radiopharmaceuticals
  • Fluorodeoxyglucose F18