Ferumoxytol enhanced black-blood cardiovascular magnetic resonance imaging

J Cardiovasc Magn Reson. 2017 Dec 28;19(1):106. doi: 10.1186/s12968-017-0422-y.

Abstract

Background: Bright-blood and black-blood cardiovascular magnetic resonance (CMR) techniques are frequently employed together during a clinical exam because of their complementary features. While valuable, existing black-blood CMR approaches are flow dependent and prone to failure. We aim to assess the effectiveness and reliability of ferumoxytol enhanced (FE) Half-Fourier Single-shot Turbo Spin-echo (HASTE) imaging without magnetization preparation pulses to yield uniform intra-luminal blood signal suppression by comparing FE-HASTE with pre-ferumoxytol HASTE imaging.

Methods: This study was IRB-approved and HIPAA compliant. Consecutive patients who were referred for FE-CMR between June 2013 and February 2017 were enrolled. Qualitative image scores reflecting the degree and reliability of blood signal suppression were based on a 3-point Likert scale, with 3 reflecting perfect suppression. For quantitative evaluation, homogeneity indices (defined as standard deviation of the left atrial signal intensity) and signal-to-noise ratios (SNR) for vascular lumens and cardiac chambers were measured.

Results: Of the 340 unique patients who underwent FE-CMR, HASTE was performed in 257. Ninety-three patients had both pre-ferumoxytol HASTE and FE-HASTE, and were included in this analysis. Qualitative image scores reflecting the degree and reliability of blood signal suppression were significantly higher for FE-HASTE images (2.9 [IQR 2.8-3.0] vs 1.8 [IQR 1.6-2.1], p < 0.001). Inter-reader agreement was moderate (k = 0.50, 95% CI 0.45-0.55). Blood signal suppression was more complete on FE-HASTE images than on pre-ferumoxytol HASTE, as indicated by lower mean homogeneity indices (24.5 [IQR 18.0-32.8] vs 108.0 [IQR 65.0-170.4], p < 0.001) and lower blood pool SNR for all regions (5.6 [IQR 3.2-10.0] vs 21.5 [IQR 12.5-39.4], p < 0.001).

Conclusion: FE-HASTE black-blood imaging offers an effective, reliable, and simple approach for flow independent blood signal suppression. The technique holds promise as a fast and routine complement to bright-blood cardiovascular imaging with ferumoxytol.

Keywords: Black-blood imaging; Ferumoxytol; HASTE; Magnetic resonance imaging; USPIO.

Publication types

  • Comparative Study
  • Evaluation Study
  • Video-Audio Media

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Blood Flow Velocity
  • Cardiovascular Diseases / diagnostic imaging*
  • Cardiovascular Diseases / physiopathology
  • Child
  • Child, Preschool
  • Contrast Media / administration & dosage*
  • Female
  • Ferrosoferric Oxide / administration & dosage*
  • Fourier Analysis
  • Humans
  • Image Interpretation, Computer-Assisted / methods*
  • Magnetic Resonance Angiography*
  • Male
  • Middle Aged
  • Observer Variation
  • Predictive Value of Tests
  • Reproducibility of Results
  • Retrospective Studies
  • Young Adult

Substances

  • Contrast Media
  • Ferrosoferric Oxide