Application of Fourier transform infrared spectroscopy with chemometrics on postmortem interval estimation based on pericardial fluids

Sci Rep. 2017 Dec 21;7(1):18013. doi: 10.1038/s41598-017-18228-7.

Abstract

Postmortem interval (PMI) evaluation remains a challenge in the forensic community due to the lack of efficient methods. Studies have focused on chemical analysis of biofluids for PMI estimation; however, no reports using spectroscopic methods in pericardial fluid (PF) are available. In this study, Fourier transform infrared (FTIR) spectroscopy with attenuated total reflectance (ATR) accessory was applied to collect comprehensive biochemical information from rabbit PF at different PMIs. The PMI-dependent spectral signature was determined by two-dimensional (2D) correlation analysis. The partial least square (PLS) and nu-support vector machine (nu-SVM) models were then established based on the acquired spectral dataset. Spectral variables associated with amide I, amide II, COO-, C-H bending, and C-O or C-OH vibrations arising from proteins, polypeptides, amino acids and carbohydrates, respectively, were susceptible to PMI in 2D correlation analysis. Moreover, the nu-SVM model appeared to achieve a more satisfactory prediction than the PLS model in calibration; the reliability of both models was determined in an external validation set. The study shows the possibility of application of ATR-FTIR methods in postmortem interval estimation using PF samples.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Autopsy*
  • Male
  • Pericardial Fluid*
  • Postmortem Changes*
  • Rabbits
  • Reproducibility of Results
  • Spectroscopy, Fourier Transform Infrared*