Application of the ISNT rules on retinal nerve fibre layer thickness and neuroretinal rim area in healthy myopic eyes

Acta Ophthalmol. 2018 Mar;96(2):161-167. doi: 10.1111/aos.13586. Epub 2017 Dec 2.

Abstract

Purpose: We determined the applicability of inferior > superior > nasal > temporal (ISNT) rules on retinal nerve fibre layer (RNFL) thickness and rim area and evaluated the impact of various ocular factors on the performance of the ISNT rules in healthy myopic eyes.

Methods: A total of 138 eyes from 138 healthy myopic subjects were included in this cross-sectional observational study. The peripapillary RNFL and optic disc in each eye were imaged with Cirrus HD optical coherence tomography (OCT) and Heidelberg Retina Tomograph II (HRT2), respectively. The performance of the inferior > superior (IS), inferior > superior > nasal > temporal (IST) and ISNT rules on RNFL thickness and rim area was determined and compared between low-to-moderate myopia and high myopia. The effects of ocular factors [including axial length, disc area, disc tilt, disc torsion, disc-fovea angle (DFA) and retina artery angle] on the performance of ISNT rules were evaluated with logistic regression analysis.

Results: The mean axial length and refractive error were 25.57 ± 1.09 mm (range, 22.52-28.77 mm) and -5.12 ± 2.30 D [range, -9.63 to -0.50 dioptres (D)], respectively. Sixty-three per cent of the healthy eyes were compliant with the ISNT rule on rim area, while ISNT rule on RNFL thickness was followed in only 11.6% of the included eyes. For rim area, smaller disc area was significantly associated with increased compliance of the IS rule (odds ratio: 0.46, p = 0.039), IST rule (odds ratio: 0.46, p = 0.037) and ISNT rule (odds ratio: 0.44, p = 0.030). For RNFL thickness, greater DFA was significantly associated with increased compliance of the IS and IST rules (odds ratio: 1.30, p < 0.001; odds ratio: 1.19, p = 0.006, respectively).

Conclusion: In healthy myopic subjects, 88.4% and 37% of eyes did not comply with the ISNT rule on RNFL thickness and rim area, respectively. Due to significant low compliance in healthy eyes, the ISNT rule and its variants have limited potential utility in diagnosing glaucoma in myopic subjects.

Keywords: Heidelberg Retina Tomograph; ISNT rule; Retina nerve fiber layer; myopia - glaucoma; neuroretinal rim area; spectral domain-OCT.

MeSH terms

  • Adolescent
  • Adult
  • Axial Length, Eye
  • Cross-Sectional Studies
  • Female
  • Glaucoma, Open-Angle / diagnosis*
  • Humans
  • Likelihood Functions
  • Male
  • Myopia / complications*
  • Nerve Fibers / pathology*
  • Ophthalmoscopy
  • Optic Nerve Diseases / diagnosis*
  • Retinal Ganglion Cells / pathology*
  • Tomography, Optical Coherence
  • Visual Fields / physiology
  • Young Adult