The OARSI core set of performance-based measures for knee osteoarthritis is reliable but not valid and responsive

Knee Surg Sports Traumatol Arthrosc. 2019 Sep;27(9):2898-2909. doi: 10.1007/s00167-017-4789-y. Epub 2017 Nov 11.

Abstract

Purpose: The Osteoarthritis Research Society International has identified a core set of performance-based tests of physical function for use in people with knee osteoarthritis (OA). The core set consists of the 30-second chair stand test (30-s CST), 4 × 10 m fast-paced walk test (40 m FPWT) and a stair climb test. The aim of this study was to evaluate the reliability, validity and responsiveness of these performance-based measures to assess the ability to measure physical function in knee OA patients.

Methods: A prospective cohort study of 85 knee OA patients indicated for total knee arthroplasty (TKA) was performed. Construct validity and responsiveness were assessed by testing of predefined hypotheses. A subgroup (n = 30) underwent test-retest measurements for reliability analysis. The Oxford Knee Score, Knee injury and Osteoarthritis Outcome Score-Physical Function Short Form, pain during activity score and knee extensor strength were used as comparator instruments. Measurements were obtained at baseline and 12 months after TKA.

Results: Appropriate test-retest reliability was found for all three tests. Intraclass correlation coefficient (ICC) for the 30-s CST was 0.90 (95% CI 0.68; 0.96), 40 m FPWT 0.93 (0.85; 0.96) and for the 10-step stair climb test (10-step SCT) 0.94 (0.89; 0.97). Adequate construct validity could not be confirmed for the three tests. For the 30-s CST, 42% of the predefined hypotheses were confirmed; for the 40 m FPWT, 27% and for the 10-step SCT 36% were confirmed. The 40 m FPWT was found to be responsive with 75% of predefined hypothesis confirmed, whereas the responsiveness for the other tests could not be confirmed. For the 30 s CST and 10-step SCT, only 50% of hypotheses were confirmed.

Conclusions: The three performance-based tests had good reliability, but poor construct validity and responsiveness in the assessment of function for the domains sit-to-stand movement, walking short distances and stair negotiation. The findings of the present study do not justify their use for clinical practice.

Level of evidence: Level 1. Diagnostic study.

Keywords: Functional outcome; Osteoarthritis; Performance-based measures; Total knee arthroplasty.

MeSH terms

  • Aged
  • Arthroplasty, Replacement, Knee / standards*
  • Exercise Test
  • Female
  • Follow-Up Studies
  • Humans
  • Knee Joint / physiopathology*
  • Knee Joint / surgery
  • Male
  • Middle Aged
  • Osteoarthritis, Knee / diagnosis*
  • Osteoarthritis, Knee / surgery
  • Pain / surgery
  • Pain Measurement
  • Preoperative Period
  • Prospective Studies
  • Range of Motion, Articular
  • Reproducibility of Results
  • Severity of Illness Index
  • Surveys and Questionnaires
  • Time Factors
  • Walk Test
  • Walking