Primary tumor volume measurements in Ewing sarcoma: MRI inter- and intraobserver variability and comparison with FDG-PET

Acta Oncol. 2018 Apr;57(4):534-540. doi: 10.1080/0284186X.2017.1398411. Epub 2017 Nov 9.

Abstract

Background: Primary tumor volume is as an important and independent prognostic factor in Ewing sarcoma. However, the observer variability of magnetic resonance imaging (MRI)-based primary tumor volume measurements in newly diagnosed Ewing sarcoma has never been investigated. Furthermore, it is unclear how MRI-based volume measurements compare to 18F-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET)-based volume measurements. This study aimed to determine the observer variability of simplified MRI-based primary tumor volume measurements in newly diagnosed treatment-naive Ewing sarcoma and to compare them to the actual primary tumor volume at MRI and the FDG-PET-based metabolically active tumor volume (MATV).

Material and methods: Twenty-nine newly diagnosed Ewing sarcoma patients with pretreatment MRI (of whom 11 also underwent FDG-PET) were included. Both exact and dichotomized (according to the proposed threshold of 200 mL) primary tumor volume measurements were analyzed.

Results: Mean inter- and intraobserver differences of MRI-based simplified tumor volume ± limits of agreement varied between 15-42 ± 155-204 mL and between 9-16 ± 64-250 mL, respectively. Inter- and intraobserver agreements of dichotomized MRI-based simplified tumor volume measurements was very good (κ = 0.827-1.000). Mean difference between simplified and actual tumor volumes at MRI ± limits of agreement was 60 ± 381 mL. Agreement between dichotomized simplified and actual tumor volumes at MRI was very good (κ = 0.839). Mean difference between MRI-based simplified tumor volume and MATV ± limits of agreement was 181 ± 549 mL and almost significantly different (p = .0581). Agreement between dichotomized MRI-based simplified tumor volume and MATV was moderate (κ = 0.560).

Conclusions: Exact MRI-based simplified primary tumor volume measurements in Ewing sarcoma suffer from considerable observer variability, but observer agreement of dichotomized measurements (≤200 mL vs. >200 mL) is very good and generally matches MRI-based actual volume measurements. MRI-based primary tumor volume measurements poorly-moderately agree with and tend to be higher than the MATV.

Publication types

  • Comparative Study

MeSH terms

  • Adolescent
  • Adult
  • Bone Neoplasms / diagnostic imaging*
  • Bone Neoplasms / pathology
  • Child
  • Child, Preschool
  • Female
  • Fluorodeoxyglucose F18
  • Humans
  • Magnetic Resonance Imaging*
  • Male
  • Middle Aged
  • Observer Variation
  • Positron-Emission Tomography*
  • Retrospective Studies
  • Sarcoma, Ewing / diagnostic imaging*
  • Sarcoma, Ewing / pathology
  • Young Adult

Substances

  • Fluorodeoxyglucose F18