Prospective longitudinal assessment of the fetal left modified Myocardial Performance Index

J Matern Fetal Neonatal Med. 2019 Mar;32(5):760-767. doi: 10.1080/14767058.2017.1391777. Epub 2017 Oct 24.

Abstract

Introduction: The fetal left modified Myocardial Performance Index (Mod-myocardial performance index (MPI)) is a measure of systolic versus diastolic time intervals obtained from a single cardiac cycle with ultrasound. It is a measure of global ventricular function and has been investigated for potential utility in fetal conditions associated with cardiac dysfunction.

Objectives: The objective of this study is to compare values from a precisely replicated fetal left Mod-MPI technique to published reference ranges.

Methods: Three hundred and sixty-five nulliparae prospectively underwent fetal left Mod-MPI measurement at 27+0-29+0 and 35+0-37+0 weeks' gestation. Measurements from pregnancies complicated by gestational diabetes mellitus, preeclampsia, or a small-for-gestational-age (<10th centile) infant were excluded. Mod-MPI values were compared with three published references created using similar measurement techniques.

Results: Compared with one selected reference, at 29+0 and 35+0-37+0 weeks' gestation, 90-100% of our values fell within the 5th-95th percentile range as expected. Thus, this reference range was validated for our population in late pregnancy. However, the expected level of concordance was not seen at 27+0-28+6 weeks'. The other two references to which we compared our Mod-MPI values demonstrated poor concordance, especially at 27+0-29+0 weeks'. Pearson interobserver correlation was also improved at 35+0-37+0 weeks' at 0.434, compared with 0.083 at 27+0-29+0 weeks' gestation.

Conclusions: Concordance and interobserver variability between our cohort and similar populations were both improved at 35+0-37+0 weeks' compared with 27+0-29+0 weeks' gestation. Overall, variable Mod-MPI reproducibility across gestations limits clinical application, especially earlier in pregnancy. Manual Mod-MPI measurement should be considered most reliable in late pregnancy until automated MPI measurement is possible.

Keywords: Doppler; MPI; echocardiography; interobserver variability; prenatal; reliability; reproducibility; ultrasonography.

MeSH terms

  • Adult
  • Cohort Studies
  • Echocardiography, Doppler
  • Female
  • Fetal Heart / diagnostic imaging*
  • Fetal Heart / physiology*
  • Gestational Age
  • Health Status Indicators*
  • Humans
  • Infant, Newborn
  • Longitudinal Studies
  • Observer Variation
  • Pregnancy
  • Prospective Studies
  • Reference Values
  • Reproducibility of Results
  • Ultrasonography, Prenatal