Background: The objective of this study is to determine the diagnostic performance of computed tomography perfusion (CTP) with and without computed tomography angiography (CTA) in assessment of hemodynamically significant coronary artery lesions in comparison to invasive fractional flow reserve (FFR).
Materials and methods: PubMed and Cochrane Center Register of Controlled Trials from January 2010 searched through December 2014. Nine original studies were selected evaluating the diagnostic performance of CTP with and without CTA to invasive coronary angiography in evaluation of hemodynamic significance of coronary lesions (n = 951).
Results: The sensitivity, specificity, LR+ and LR- and DOR of CTA+CTP were 0.85 [95% confidence interval (CI: 0.79-0.89)] 0.94 (CI: 0.91-0.97), 15.8 (CI: 7.99-31.39), 0.146 (CI: 0.08-0.26), and 147.2 (CI: 69.77-310.66). Summary Receiver Operating Characteristics (SROC) results showed area under the curve (AUC) of 0.97 indicating that CTA+CTP may detect hemodynamically significant coronary artery lesions with high accuracy. The sensitivity, specificity, LR+ and LR- and DOR of CTP were 0.83 (CI: 0.78-0.87), 0.84 (CI: 0.80-0.87) 5.26 (CI: 2.93-9.43), 0.209 (CI: 0.12-0.36), and 31.97 (CI: 11.59-88.20).
Conclusions: This result suggests that CTP with CTA significantly improves diagnostic performance of coronary artery lesions compared to CTA alone and closely comparable with invasive FFR.
Keywords: Computed tomography angiography; Computed tomography perfusion; Coronary artery lesion; Diagnostic accuracy; Fractional flow reserve.