Whole-tumor histogram analysis of the cerebral blood volume map: tumor volume defined by 11C-methionine positron emission tomography image improves the diagnostic accuracy of cerebral glioma grading

Jpn J Radiol. 2017 Oct;35(10):613-621. doi: 10.1007/s11604-017-0675-2. Epub 2017 Sep 6.

Abstract

Purpose: This study aimed to compare the tumor volume definition using conventional magnetic resonance (MR) and 11C-methionine positron emission tomography (MET/PET) images in the differentiation of the pre-operative glioma grade by using whole-tumor histogram analysis of normalized cerebral blood volume (nCBV) maps.

Materials and methods: Thirty-four patients with histopathologically proven primary brain low-grade gliomas (n = 15) and high-grade gliomas (n = 19) underwent pre-operative or pre-biopsy MET/PET, fluid-attenuated inversion recovery, dynamic susceptibility contrast perfusion-weighted magnetic resonance imaging, and contrast-enhanced T1-weighted at 3.0 T. The histogram distribution derived from the nCBV maps was obtained by co-registering the whole tumor volume delineated on conventional MR or MET/PET images, and eight histogram parameters were assessed.

Results: The mean nCBV value had the highest AUC value (0.906) based on MET/PET images. Diagnostic accuracy significantly improved when the tumor volume was measured from MET/PET images compared with conventional MR images for the parameters of mean, 50th, and 75th percentile nCBV value (p = 0.0246, 0.0223, and 0.0150, respectively).

Conclusion: Whole-tumor histogram analysis of CBV map provides more valuable histogram parameters and increases diagnostic accuracy in the differentiation of pre-operative cerebral gliomas when the tumor volume is derived from MET/PET images.

Keywords: Dynamic susceptibility contrast MRI; Glioma; Histogram analysis; Methionine; Normalized cerebral blood volume (nCBV).

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Brain / diagnostic imaging
  • Brain / pathology
  • Brain Mapping / methods
  • Brain Neoplasms / blood supply
  • Brain Neoplasms / diagnostic imaging*
  • Brain Neoplasms / pathology*
  • Carbon Radioisotopes
  • Cerebral Blood Volume / physiology*
  • Female
  • Glioma / blood supply
  • Glioma / diagnostic imaging*
  • Glioma / pathology*
  • Humans
  • Magnetic Resonance Imaging / methods
  • Male
  • Methionine
  • Middle Aged
  • Neoplasm Grading
  • Positron-Emission Tomography / methods*
  • Reproducibility of Results
  • Tumor Burden
  • Young Adult

Substances

  • Carbon Radioisotopes
  • Carbon-11
  • Methionine