Polymer-free amphilimus-eluting stent versus biodegradable polymer biolimus-eluting stent in patients with and without diabetes mellitus

Int J Cardiol. 2017 Oct 15:245:69-76. doi: 10.1016/j.ijcard.2017.06.028.

Abstract

Objectives: This study sought to compare clinical outcome of polymer-free amphilimus-eluting stent (PF-AES) versus biodegradable-polymer biolimus-eluting stent (BD-BES) in "all-comer" diabetes mellitus (DM) and non-DM patients who underwent percutaneous coronary intervention.

Background: The PF-AES has shown promising preliminary results in patients with DM.

Methods: Data from 2 multicentre-national registries (the ASTUTE and the INSPIRE-1) were used to analyse 1776 patients stratified in non-DM and DM. A double 1:1 propensity-score matched analysis (PF-AES vs. BD-BES) was performed in each group to adjust for clinical and procedural characteristics. Primary stent-efficacy and stent-safety endpoints were 1-year target-lesion revascularization (TLR) and target-lesion failure (TLF, composed of cardiac-death, target-vessel myocardial infarction and any TLR).

Results: After propensity-score matching, 850 patients were stratified as non-DM (425 PF-AES/425 BD-BES) and 480 as DM patients (240 PF-AES/240 BD-BES). Both TLF (20 of 425 [5%] vs. 24 of 425 [6%]; Plog-rank=0.527) and TLR (9 of 425 [2%] vs. 18 of 425 [4%]; Plog-rank=0.079) were similar between PF-AES and BD-BES in non-DM patients. In DM, TLF (12 of 240 [5%] vs. 31 of 240 [13%]; Plog-rank=0.002) and TLR (9 of 240 [4%] vs. 21 of 240 [9%]; Plog-rank=0.019) were significantly lower in PF-AES compared to BD-BES. Upon multivariate analysis, the most powerful predictors of TLF were chronic kidney disease in non-DM (OR 4.24, 95% CI: 2.07-8.70, p<0.001) and stent type in DM patients (OR 2.76, 1.36-5.56, p=0.005).

Conclusions: This matched-cohort study suggests that PF-AES has better safety and efficacy profile than BD-BES in patients with DM.

Keywords: Biodegradable polymer biolimus eluting stent; Diabetes mellitus; Percutaneous coronary intervention; Polymer-free amphilimus eluting stent.

Publication types

  • Comparative Study
  • Multicenter Study
  • Observational Study

MeSH terms

  • Absorbable Implants / standards*
  • Aged
  • Anti-Inflammatory Agents / administration & dosage
  • Cohort Studies
  • Coronary Artery Disease / epidemiology
  • Coronary Artery Disease / physiopathology
  • Coronary Artery Disease / surgery*
  • Diabetes Mellitus / epidemiology
  • Diabetes Mellitus / physiopathology
  • Diabetes Mellitus / surgery*
  • Drug-Eluting Stents / standards*
  • Female
  • Follow-Up Studies
  • Humans
  • Male
  • Middle Aged
  • Percutaneous Coronary Intervention / methods
  • Percutaneous Coronary Intervention / standards
  • Polymers*
  • Registries
  • Sirolimus / administration & dosage
  • Sirolimus / analogs & derivatives*

Substances

  • Anti-Inflammatory Agents
  • Polymers
  • umirolimus
  • Sirolimus