Analysis of individual and total microcystins in surface water by on-line preconcentration and desalting coupled to liquid chromatography tandem mass spectrometry

J Chromatogr A. 2017 Sep 22:1516:9-20. doi: 10.1016/j.chroma.2017.07.096. Epub 2017 Aug 5.

Abstract

A fast and high-throughput method is proposed for the determination of total microcystins (ΣMC) in environmental surface waters. After a 1-h Lemieux-von Rudloff oxidation step to yield the 2-methyl-3-methoxy-4-phenylbutyric acid (MMPB) moiety, samples were quenched, filtered, and directly analyzed. This was achieved via solid phase extraction (SPE) coupled on-line to ultra-high performance liquid chromatography electrospray ionization triple stage quadrupole mass spectrometry. The choice of on-line SPE settings was conducted using experimental designs. Given the matrix complexity of oxidation extracts, the on-line desalting step was found to be a critical parameter to ensure suitable method robustness. The on-line sample loading volume was 5mL, and the wash volume applied for on-line desalting was 3mL. Instrumental analysis was performed in just 8min. The method limit of quantification was 0.5ngL-1 ΣMC (i.e. 2000 times lower than the current World Health Organization - WHO drinking water guideline). Excellent determination coefficients were observed for matrix-free and matrix-based calibration curves alike, and the linearity range tested spanned∼4 orders of magnitude. Accuracy and intermediate precision did not depend on the spike level and proved satisfactory (in the range of 93-110% and 3-6%, respectively). A thorough assessment of instrumental matrix effects was conducted by comparing standard additions curves in several lake and river oxidation extracts with the matrix-free reference. Regardless of the internal standard used (4-PB or D3-MMPB), instrumental matrix effects were efficiently compensated. The matrix effect that may occur at the earlier sample preparation stage was evaluated separately. While the oxidation step was generally not complete (yield ∼65%), the conversion rates of MCs into MMPB remained within a consistent range of values regardless of matrix type. No significant back-pressure was observed upon consecutive injections of oxidation-based samples, while the instrumental sensitivity remained unaffected. The herein described method could therefore be eligible for future large-scale monitoring surveys. The method was applied to a selection of surface water samples (n=30) collected across the province of Québec, Canada, and the results were compared to those achieved by an individual variant analysis of 8 MC congeners and a commercial ELISA kit.

Keywords: Cyanotoxins; Lemieux oxidation; Matrix effect assessment; Method validation; On-line enrichment and desalting; Surface water; Total microcystins via MMPB.

MeSH terms

  • Canada
  • Chromatography, High Pressure Liquid*
  • Environmental Monitoring / methods*
  • Lakes / chemistry*
  • Microcystins / analysis*
  • Phenylbutyrates / chemistry
  • Quebec
  • Reproducibility of Results
  • Solid Phase Extraction / methods
  • Tandem Mass Spectrometry*
  • Water Pollutants, Chemical / analysis*

Substances

  • Microcystins
  • Phenylbutyrates
  • Water Pollutants, Chemical
  • 4-phenylbutyric acid
  • 2-phenylbutyric acid