A Critical Care Clinician Survey Comparing Attitudes and Perceived Barriers to Low Tidal Volume Ventilation with Actual Practice

Ann Am Thorac Soc. 2017 Nov;14(11):1682-1689. doi: 10.1513/AnnalsATS.201612-973OC.

Abstract

Rationale: Low-Vt ventilation lowers mortality in patients with acute respiratory distress syndrome (ARDS) but is underused. Little is known about clinician attitudes toward and perceived barriers to low-Vt ventilation use and their association with actual low-Vt ventilation use.

Objectives: The objectives of this study were to assess clinicians' attitudes toward and perceived barriers to low-Vt ventilation (Vt <6.5 ml/kg predicted body weight) in patients with ARDS, to identify differences in attitudes and perceived barriers among clinician types, and to compare attitudes toward and perceived barriers to actual low-Vt ventilation use in patients with ARDS.

Methods: We conducted a survey of critical care physicians, nurses, and respiratory therapists at four non-ARDS Network hospitals in the Chicago region. We compared survey responses with performance in a cohort of 362 patients with ARDS.

Results: Survey responses included clinician attitudes toward and perceived barriers to low-Vt ventilation use. We also measured low-Vt ventilation initiation by these clinicians in 347 patients with ARDS initiated after ARDS onset as well as correlation with clinician attitudes and perceived barriers. Of 674 clinicians surveyed, 467 (69.3%) responded. Clinicians had positive attitudes toward and perceived few process barriers to ARDS diagnosis or initiation of low-Vt ventilation. Physicians had more positive attitudes and perceived fewer barriers than nurses or respiratory therapists. However, use of low-Vt ventilation by all three clinician groups was low. For example, whereas physicians believed that 92.5% of their patients with ARDS warranted treatment with low-Vt ventilation, they initiated low-Vt ventilation for a median (interquartile range) of 7.4% (0 to 14.3%) of their eligible patients with ARDS. Clinician attitudes and perceived barriers were not correlated with low-Vt ventilation initiation.

Conclusions: Clinicians had positive attitudes toward low-Vt ventilation and perceived few barriers to using it, but attitudes and perceived process barriers were not correlated with actual low-Vt ventilation use, which was low. Implementation strategies should be focused on examining other issues, such as ARDS recognition and process solutions, to improve low-Vt ventilation use.

Keywords: acute respiratory distress syndrome; intensive care unit; quality improvement; survey.

Publication types

  • Multicenter Study

MeSH terms

  • Adult
  • Aged
  • Attitude of Health Personnel*
  • Chicago
  • Critical Care / organization & administration
  • Female
  • Humans
  • Male
  • Middle Aged
  • Respiration, Artificial / methods*
  • Respiratory Distress Syndrome / mortality
  • Respiratory Distress Syndrome / therapy*
  • Surveys and Questionnaires
  • Tidal Volume
  • Young Adult