Comparison between sEMG and force as control interfaces to support planar arm movements in adults with Duchenne: a feasibility study

J Neuroeng Rehabil. 2017 Jul 12;14(1):73. doi: 10.1186/s12984-017-0282-6.

Abstract

Background: Adults with Duchenne muscular dystrophy (DMD) can benefit from devices that actively support their arm function. A critical component of such devices is the control interface as it is responsible for the human-machine interaction. Our previous work indicated that surface electromyography (sEMG) and force-based control with active gravity and joint-stiffness compensation were feasible solutions for the support of elbow movements (one degree of freedom). In this paper, we extend the evaluation of sEMG- and force-based control interfaces to simultaneous and proportional control of planar arm movements (two degrees of freedom).

Methods: Three men with DMD (18-23 years-old) with different levels of arm function (i.e. Brooke scores of 4, 5 and 6) performed a series of line-tracing tasks over a tabletop surface using an experimental active arm support. The arm movements were controlled using three control methods: sEMG-based control, force-based control with stiffness compensation (FSC), and force-based control with no compensation (FNC). The movement performance was evaluated in terms of percentage of task completion, tracing error, smoothness and speed.

Results: For subject S1 (Brooke 4) FNC was the preferred method and performed better than FSC and sEMG. FNC was not usable for subject S2 (Brooke 5) and S3 (Brooke 6). Subject S2 presented significantly lower movement speed with sEMG than with FSC, yet he preferred sEMG since FSC was perceived to be too fatiguing. Subject S3 could not successfully use neither of the two force-based control methods, while with sEMG he could reach almost his entire workspace.

Conclusions: Movement performance and subjective preference of the three control methods differed with the level of arm function of the participants. Our results indicate that all three control methods have to be considered in real applications, as they present complementary advantages and disadvantages. The fact that the two weaker subjects (S2 and S3) experienced the force-based control interfaces as fatiguing suggests that sEMG-based control interfaces could be a better solution for adults with DMD. Yet force-based control interfaces can be a better alternative for those cases in which voluntary forces are higher than the stiffness forces of the arms.

Keywords: Arm support; Assistive device; Control interface; Duchenne; Force control; Stiffness compensation; sEMG control.

Publication types

  • Comparative Study

MeSH terms

  • Adolescent
  • Algorithms
  • Arm*
  • Electromyography / methods*
  • Feasibility Studies
  • Female
  • Humans
  • Male
  • Models, Theoretical
  • Movement*
  • Muscular Dystrophy, Duchenne / rehabilitation*
  • Patient Preference
  • Prosthesis Design
  • Psychomotor Performance
  • Robotics
  • Self-Help Devices*
  • Signal Processing, Computer-Assisted
  • Young Adult