One-year efficacy and safety of the Trufill DCS Orbit and Orbit Galaxy detachable coils in the endovascular treatment of intracranial aneurysms: Results from the TRULINE study

Interv Neuroradiol. 2017 Oct;23(5):485-491. doi: 10.1177/1591019917717576. Epub 2017 Jul 4.

Abstract

Background and purpose No series reported the mid-term results of Trufill DCS Orbit and Orbit Galaxy detachable coils with independent evaluation. We present the one-year safety and efficacy of these coils in real-life routine clinical practice. Methods A total of 167 patients with 167 aneurysms (39.1% ruptured) were enrolled in the prospective TRULINE study. The primary endpoint was the safety, assessed by the combined morbidity-mortality rate observed since the time of the procedure and up to one-year follow-up. For safety, primary analyses were performed on intent-to-treat population (attempted coils procedure) and all adverse events have been reviewed by an independent Data Safety Monitoring Board. For efficacy, primary analyses were performed on the per-protocol population (patients treated with more than 70% of Trufill coils and not retreated during the follow-up period) and an independent core laboratory evaluated angiographic results. Results At one-year post-procedure, neurologic impairment was observed in 6.5% (95% confidence interval: 3.5-11.8) of the patients, and 2.6% (95% confidence interval: 1.0-6.8) had a permanent neurological deterioration. Three deaths were observed, unrelated to the procedure or coils. At one year, complete occlusion was seen in 52 aneurysms (54.2%), neck remnant in 28 aneurysms (29.2%), and aneurysm remnant in 16 aneurysms (16.7%). During the one-year follow-up, the overall incidence of recurrence was 30.2% with a mean interval of 13.8 ± 4.5 months and the retreatment for major recanalization was needed in nine patients (6.3%). Conclusions The TRULINE study confirms that endovascular coiling with Trufill DCS Orbit and Orbit Galaxy detachable coils is safe and effective.

Keywords: Intracranial aneurysms; coiling; endovascular treatment; recanalization.

Publication types

  • Multicenter Study
  • Observational Study

MeSH terms

  • Aged
  • Aneurysm, Ruptured / diagnostic imaging
  • Aneurysm, Ruptured / mortality
  • Aneurysm, Ruptured / therapy*
  • Cerebral Angiography
  • Embolization, Therapeutic / instrumentation*
  • Female
  • France
  • Humans
  • Intracranial Aneurysm / diagnostic imaging
  • Intracranial Aneurysm / mortality
  • Intracranial Aneurysm / therapy*
  • Male
  • Middle Aged
  • Prospective Studies
  • Recurrence
  • Treatment Outcome