Since contrast sensitivity (CS) relies on the accuracy of stimulus presentation, the reliability of the psychophysical procedure and observer's attention, the measurement of the CS-function is critical and therefore, a useful threshold contrast measurement was developed. The Tuebingen Contrast Sensitivity Test (TueCST) includes an adaptive staircase procedure and a 16-bit gray-level resolution. In order to validate the CS measurements with the TueCST, measurements were compared with existing tests by inter-test repeatability, test-retest reliability and time. The novel design enables an accurate presentation of the spatial frequency and higher precision, inter-test repeatability and test-retest reliability compared to other existing tests.
Keywords: (330.0330) Vision, color, and visual optics; (330.1800) Vision - contrast sensitivity.