Sci-Fri AM: Imaging - 03: Temperature dependence of a SiPM detector for an MR compatible PET system

Med Phys. 2012 Jul;39(7Part4):4640. doi: 10.1118/1.4740189.

Abstract

Silicon photomultiplier (SiPM) detectors are rapidly becoming the detector of choice for research and development of new detectors for positron emission tomography (PET) due to their combination of high gain, fast timing, compact form factor and ability to function in a magnetic field. We are investigating using SiPM based detectors in a compact PET system designed to be inserted into a 7T animal MRI system and enable simultaneous PET/MRI imaging. In order to understand the level of thermal stability required for this PET system, we examined the stability of a prototype SiPM detector vs. temperature. A detector was constructed using a SensL SPMArray4 SiPM array coupled to a LYSO scintillator crystal array. The temperature of the detector was varied between 23 and 60°C in 5°C steps. At each temperature setting data were collected to characterize the detector flood histogram, photopeak amplitude and energy resolution at 511 keV, timing resolution and signal arrival time. While the flood image showed no noticeable changes with temperature, the 511 keV photopeak amplitude showed a linear decrease of 1.5%/°C and the energy resolution degraded by 0.08%/°C. The timing resolution degraded by 1.5 ns, from 3.5 ns to 5 ns when the temperature changed from 23 to 60°C. Over this temperature range there was a shift in the signal arrival time of approximately 3 ns. These results demonstrate that the detector can be operated over a wide range of temperature, giving a large degree of flexibility in choosing an operating temperature set-point for our PET system.

Keywords: Form factors; Image detection systems; Image sensors; Magnetic field sensors; Magnetic resonance imaging; Photomultipliers; Positron emission tomography; Scintillation detectors; Silicon; Silicon detectors.