Abstract

Aim: To investigate the dose-length product (DLP) during intracranial computed tomography angiography (CTA) using a patient-specific contrast formula.

Materials and methods: Intracranial CTA was performed on 120 patients using 64-channel CT. Patients were subjected in equal numbers to one of two acquisitions/contrast medium protocols. Protocol A, consisted of 80 ml contrast medium and protocol B, involved a novel contrast medium formula. In each protocol, contrast medium and saline were injected at a flow rate of 4.5 ml/s. The DLP and contrast volume (CV) were measured between each protocol and the data obtained were compared using two-tailed independent t-test.

Results: Mean arterial vessel attenuation was up to 56% (p<0.01) higher using protocol B compared with A. In the venous system, the mean vessel attenuation was significantly lower in protocol B than A with a maximum reduction of 93% (p<0.001). The mean CV was significantly lower in protocol B (53±10 ml) compared to A (80±1 ml, p<0.001). The scan time was equal in each protocol (B, 4.22±1.2 seconds; A, 4.01±1.3 seconds). A significant reduction in mean DLP was demonstrated in protocol B (3.99±0.22 mSv) compared to A (4.74±0.22 mSv; p=0.02).

Conclusion: A significant reduction in CV and DLP during intracranial CTA can be achieved when employing a patient-specific contrast medium formula.

Publication types

  • Randomized Controlled Trial

MeSH terms

  • Cerebrovascular Circulation*
  • Computed Tomography Angiography / methods*
  • Contrast Media / administration & dosage*
  • Female
  • Humans
  • Iohexol / administration & dosage
  • Iohexol / analogs & derivatives*
  • Male
  • Prospective Studies
  • Radiation Dosage*
  • Radiographic Image Interpretation, Computer-Assisted
  • Stroke / diagnostic imaging*

Substances

  • Contrast Media
  • Iohexol
  • iopromide