High performance refractive index sensor based on low Q-factor ring resonators and FFT processing of wavelength scanning data

Opt Express. 2017 Apr 3;25(7):7483-7495. doi: 10.1364/OE.25.007483.

Abstract

We extend our previous simulation study and we present experimental results regarding our Fast Fourier Transform method for the calculation of the resonance shifts in biosensors based on micro-ring resonators (MRRs). For the simulation study, we use a system model with a tunable laser at 850 nm, an MRR with 1.5∙104 quality factor, and a detection system with 50 dB maximum signal-to-noise ratio, and investigate the impact on the system performance of factors like the number of the resonance peaks inside the scanning window, the wavelength dependence of the laser power, and the asymmetry of the transfer functions of the MRRs. We find that the performance is improved by a factor of 2 when we go from single- to four-peak transfer functions, and that the impact of the wavelength dependence of the laser power is very low. We also find that the presence of asymmetries can lead to strong discontinuities of the transfer functions at the edges of the scanning window and can significantly increase the measurement errors, making necessary the use of techniques for their elimination. Using these conclusions, we build a system with sensing MRRs on TriPleX platform, and we experimentally validate our method using sucrose solutions with different concentrations. Involving techniques in order to exclude the noise originating from the microfluidic system, we achieve a wavelength resolution close to 0.08 pm, when the system operates with 0.5 pm scanning step. In combination with the sensitivity of the MRRs, which is measured to be equal to 93.7 nm/RIU, this wavelength resolution indicates the possibility for a limit of detection close to 8.5·10-7 RIU, which represents to the best of our knowledge a record performance for this type of optical sensors and this level of scanning steps.