Under-utilization of taps in intensive care unit as a cause of reservoirs of nonfermenting gram-negative bacilli

Enferm Infecc Microbiol Clin (Engl Ed). 2018 Apr;36(4):214-217. doi: 10.1016/j.eimc.2017.01.008. Epub 2017 Mar 11.
[Article in English, Spanish]

Abstract

Introduction: The under-utilisation of taps is associated with the generation of reservoirs of non-fermenting gram-negative bacilli with the ability to disseminate. We describe the detection and approach of the problem in an ICU.

Methods: Observational descriptive study in an ICU with individual cubicles with their own sink. We collected clinical samples from patients and environmental samples from tap aerators and reviewed the unit's hygiene measures.

Results: We detected four cases due to Chryseobacterium indologenes, one to Elizabethkingia meningoseptica and another to Pseudomonas aeruginosa; they were identified both in clinical and the environmental samples. The healthcare professionals reported that almost every hand hygiene opportunity was performed with a hydroalcoholic solution. After considered the daily flushing of water outlets as inefficient, it was decided to remove them.

Conclusions: National recommendations were insufficient for preventing, detecting and controlling tap contamination in units with a high risk of infection. The management of taps in these units needs to be improved.

Keywords: Aireador de grifo; Bacilo gramnegativo no fermentador; Intensive care unit; Non-fermenting gram-negative bacilli; Surveillance; Tap aerator; Unidad de cuidados intensivos; Vigilancia.