Association of global and disease-specific health status with outcomes following continuous-flow left ventricular assist device implantation

BMC Cardiovasc Disord. 2017 Mar 14;17(1):78. doi: 10.1186/s12872-017-0510-9.

Abstract

Background: The prognostic value of heart failure specific and global health status before and after left ventricular assist device (LVAD) implantation in the usual care setting is not well studied.

Methods: We included 3,836 continuous-flow LVAD patients in the INTERMACS registry. Health status was measured pre-operatively and 3 months post-LVAD using the Kansas City Cardiomyopathy Questionnaire (KCCQ) and EuroQol visual analog scale (VAS). Primary outcomes were mortality/rehospitalization. Inverse propensity weighting was used to minimize bias from missing data.

Results: Pre-operative global and heart failure-specific health status were very poor: KCCQ median 34.6 (IQR 21.4-50.5); VAS median 43 (interquartile range (IQR) 25-65). Health status measures improved 3 months after LVAD placement: KCCQ median 69.3 (IQR 54.2-82.3); VAS median 75 (IQR 60-85). Pre-operative health status was not associated with death (unadjusted HR for lowest vs. highest score quartiles: 1.09 (0.85-1.41) KCCQ; 1.12 (0.85-1.49) VAS) or rehospitalization (unadjusted HR 0.83 (0.72-0.96) KCCQ; 0.99 (0.85-1.16) VAS). Three-month KCCQ was associated with mortality (unadjusted HR 2.17 (1.47-3.21); VAS was not (1.43 (0.94-2.17). Three-month KCCQ added incremental discriminatory value to the HeartMate II Risk Score for death (c-stat 0.60 to 0.66); VAS did not (c-stat 0.59 to 0.60). Three-month health status was associated with rehospitalization (unadjusted HR 1.31 (1.15-1.57) KCCQ; 1.24 (1.05-1.46) VAS), but did not add incremental discriminatory value (c-stat 0.52 to 0.55 and 0.54, respectively).

Conclusions: These real-world data suggest that pre-operative health status has limited association with outcomes after LVAD. However, persistently low health status after surgery may independently signal higher risk for subsequent death. Further study is needed to determine the clinical utility of routinely collected health status data after LVAD implantation.

Keywords: Health status; Heart failure; Left ventricular assist device; Mechanical circulatory support; Quality of life.

Publication types

  • Multicenter Study
  • Research Support, N.I.H., Extramural

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Female
  • Follow-Up Studies
  • Health Status*
  • Heart Failure / epidemiology
  • Heart Failure / physiopathology
  • Heart Failure / surgery*
  • Heart Ventricles / physiopathology*
  • Heart-Assist Devices*
  • Humans
  • Male
  • Middle Aged
  • Patient Readmission / trends
  • Prognosis
  • Prospective Studies
  • Quality of Life*
  • Registries*
  • Surveys and Questionnaires
  • Survival Rate / trends
  • Time Factors
  • Treatment Outcome
  • United States / epidemiology
  • Ventricular Function, Left / physiology*
  • Young Adult