Obtaining the biomechanical behavior of ascending aortic aneurysm via the use of novel speckle tracking echocardiography

J Thorac Cardiovasc Surg. 2017 Apr;153(4):781-788. doi: 10.1016/j.jtcvs.2016.11.056. Epub 2016 Dec 20.

Abstract

Introduction: Ex vivo measurement of ascending aortic biomechanical properties may help understand the risk for rupture or dissection of dilated ascending aortas. A validated in vivo method that can predict aortic biomechanics does not exist. Speckle tracking transesophageal echocardiography (TEE) has been used to measure ventricular stiffness; we sought to determine whether speckle TEE could be adapted to estimate aortic stiffness in vivo and compare these findings with those obtained by ex vivo tissue measurements.

Methods: A total of 17 patients undergoing ascending aortic resection were recruited to with a mean aortic diameter was 56.16 ± 15 mm. Intraoperative speckle TEE tracking analysis was used to calculate aortic stiffness index using the following equation: β2=ln(SBP/DBP)/AoS, where β2 is the stiffness index; SBP is systolic blood pressure; DBP is diastolic blood pressure; and AoS is the circumferential strain. Ex vivo stiffness was obtained by mechanical tissue testing according to previously described methods. The aortic ring at the pulmonary trunk was divided into 4 equal quadrants.

Results: The in vivo stiffness index for the inner curvature, anterior wall, outer curvature, and posterior wall were 0.0544 ± 0.0490, 0.0295 ± 0.0199, 0.0411 ± 0.0328, and 0.0502 ± 0.0320, respectively. The mean ex vivo 25% apparent stiffness for inner curvature, anterior wall, outer curvature, and posterior wall were 0.0616 ± 0.0758 MPa, 0.0352 ± 0.00992 MPa, 0.0405 ± 0.0199 MPa, and 0.0327 ± 0.0106 MPa, respectively. The patient-matched ex vivo 25% apparent stiffness and in vivo stiffness index were not significantly different (P = .8617, 2-way analysis of variance with repeated measures).

Conclusions: The use of speckle TEE appears to be a promising technique to estimate ex vivo mechanical properties of the ascending aortic tissue.

Keywords: aneurysm; aorta; biomechanics; echo speckle tracing; risk of rupture.

Publication types

  • Video-Audio Media

MeSH terms

  • Aged
  • Aorta / diagnostic imaging*
  • Aorta / physiopathology
  • Aorta / surgery
  • Aortic Aneurysm / diagnostic imaging*
  • Aortic Aneurysm / physiopathology
  • Aortic Aneurysm / surgery
  • Biomechanical Phenomena
  • Echocardiography / methods*
  • Echocardiography, Transesophageal
  • Female
  • Hemodynamics*
  • Humans
  • Male
  • Middle Aged
  • Predictive Value of Tests
  • Vascular Stiffness*