Rupture of Pseudo aneurysm of Popliteal vessels due to pin migration of External Fixator- A Rare Case Report

Oman Med J. 2010 Jul;25(3):e005. doi: 10.5001/omj.2010.74.

Abstract

External fixators for fracture stabilization or limb lengthening cause complications such as pseudoaneurysm, acute ischemia, bleeding, compartment syndrome, and arterio venous fistula. This is a report of a patient who sustained open fracture of both bones of the right leg and the recovery period was complicated by a rare complication where migration of the proximal pin of external fixator into the popliteal vessels and caused rupture of pseudoaneurysm with popliteal vessels injury after a trivial trauma.

Keywords: External fixator; Pin migration; Popliteal vessels; Pseudoaneurysm.

Publication types

  • Case Reports