Indirect reduction technique using a distraction support in minimally invasive percutaneous plate osteosynthesis of tibial shaft fractures

Chin J Traumatol. 2016 Dec 1;19(6):348-352. doi: 10.1016/j.cjtee.2016.09.001.

Abstract

Purpose: To describe an indirect reduction technique during minimally invasive percutaneous plate osteosynthesis (MIPPO) of tibial shaft fractures with the use of a distraction support.

Methods: Between March 2011 and October 2014, 52 patients with a mean age of 48 years (16-72 years) sustaining tibial shaft fractures were included. All the patients underwent MIPPO for the fractures using a distraction support prior to insertion of the plate. Fracture angular deformity was assessed by goni- ometer measurement on preoperative and postoperative images.

Results: Preoperative radiographs revealed a mean of 7.6°(1.2°-28°) angulation in coronal plane and a mean of 6.8°(0.5°-19°) angulation in sagittal plane. Postoperative anteroposterior and lateral radio- graphs showed a mean of 0.8°(0°-4.0°) and 0.6°(0°-3.6°) of varus/valgus and apex anterior/posterior angulation, respectively. No intraoperative or postoperative complications were noted.

Conclusions: This study suggests that the distraction support during MIPPO of tibial shaft fractures is an effective and safe method with no associated complications.

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Bone Plates*
  • Fracture Fixation, Internal / adverse effects
  • Fracture Fixation, Internal / methods*
  • Humans
  • Middle Aged
  • Minimally Invasive Surgical Procedures / methods*
  • Tibial Fractures / surgery*