ELECTRON ABSORBED FRACTIONS IN AN IMAGE-BASED MICROSCOPIC SKELETAL DOSIMETRY MODEL OF CHINESE ADULT MALE

Radiat Prot Dosimetry. 2017 Aug 1;175(4):450-459. doi: 10.1093/rpd/ncw372.

Abstract

Based on the Chinese reference adult male voxel model, a set of microscopic skeletal models of Chinese adult male is constructed through the processes of computed tomography (CT) imaging, bone coring, micro-CT imaging, image segmentation, merging into macroscopic bone model and implementation in Geant4. At the step of image segmentation, a new bone endosteum (BE) segmentation method is realized by sampling. The set of model contains 32 spongiosa samples with voxel size of 19 μm cubes. The microscopic spongiosa bone data for Chinese adult male are provided. Electron absorbed fractions in red bone marrow (RBM) and BE are calculated. Source tissues include the bone marrow (red and yellow), trabecular bone (surfaces and volumes) and cortical bone (surfaces and volumes). Target tissues include RBM and BE. Electron energies range from 10 keV to 10 MeV. Additionally, comparison of the result with other investigations is provided.

MeSH terms

  • Adult
  • Bone Marrow
  • Bone and Bones
  • Electrons*
  • Humans
  • Male
  • Radiometry*
  • Tomography, X-Ray Computed*