Bunch-by-bunch position measurement and analysis at PLS-II

J Synchrotron Radiat. 2017 Jan 1;24(Pt 1):163-167. doi: 10.1107/S1600577516018154. Epub 2017 Jan 1.

Abstract

A bunch-by-bunch measurement system has been developed at Pohang Light Source II. The system consists of a four-channel button pick-up, 20 GHz sampling oscilloscope and an 800 MHz low-pass digital filter. Upon measuring a bunch-by-bunch spatio-temporal beam motion matrix over many turns, singular-value decomposition analysis is used to reveal the dominant coupled-bunch modes. The system can diagnose injection oscillations due to kicker errors and the effect of resistive-wall impedance that gives rise to instability during operation.

Keywords: bunch by bunch; instability; position.