Accuracy of Jump-Mat Systems for Measuring Jump Height

Int J Sports Physiol Perform. 2017 Aug;12(7):959-963. doi: 10.1123/ijspp.2016-0511. Epub 2016 Dec 14.

Abstract

Vertical-jump tests are commonly used to evaluate lower-limb power of athletes and nonathletes. Several types of equipment are available for this purpose.

Purpose: To compare the error of measurement of 2 jump-mat systems (Chronojump-Boscosystem and Globus Ergo Tester) with that of a motion-capture system as a criterion and to determine the modifying effect of foot length on jump height.

Methods: Thirty-one young adult men alternated 4 countermovement jumps with 4 squat jumps. Mean jump height and standard deviations representing technical error of measurement arising from each device and variability arising from the subjects themselves were estimated with a novel mixed model and evaluated via standardization and magnitude-based inference.

Results: The jump-mat systems produced nearly identical measures of jump height (differences in means and in technical errors of measurement ≤1 mm). Countermovement and squat-jump height were both 13.6 cm higher with motion capture (90% confidence limits ±0.3 cm), but this very large difference was reduced to small unclear differences when adjusted to a foot length of zero. Variability in countermovement and squat-jump height arising from the subjects was small (1.1 and 1.5 cm, respectively, 90% confidence limits ±0.3 cm); technical error of motion capture was similar in magnitude (1.7 and 1.6 cm, ±0.3 and ±0.4 cm), and that of the jump mats was similar or smaller (1.2 and 0.3 cm, ±0.5 and ±0.9 cm).

Conclusions: The jump-mat systems provide trustworthy measurements for monitoring changes in jump height. Foot length can explain the substantially higher jump height observed with motion capture.

Keywords: contact mat; jump performance; modeling; motion capture; open-source technology; reliability.

Publication types

  • Observational Study

MeSH terms

  • Adolescent
  • Adult
  • Athletic Performance*
  • Exercise Test / instrumentation*
  • Foot
  • Humans
  • Male
  • Reproducibility of Results