Imaging Guidance Improves the Results of Viscosupplementation with HANOX-M-XL in Patients with Ankle Osteoarthritis: Results of a Clinical Survey in 50 Patients Treated in Daily Practice

Clin Med Insights Arthritis Musculoskelet Disord. 2016 Nov 22:9:195-199. doi: 10.4137/CMAMD.S40401. eCollection 2016.

Abstract

Background: The objective of this survey was to assess retrospectively the interest of performing viscosupplementation using imaging guidance in patients suffering from ankle osteoarthritis (OA).

Patients and methods: This is a multicenter retrospective survey using a standardized questionnaire. Fifty patients suffering from ankle OA and treated, in daily clinical practice, with a single intra-articular injection of a novel viscosupplement made of a combination of a non-animal cross-linked hyaluronan and mannitol, HANOX M-XL, were included in the survey. The injection procedure (imaging or landmark guidance), demographic data, patient's self-evaluation of pain, satisfaction, treatment efficacy, and tolerability were collected. Predictive factors of both efficacy and patient's satisfaction were investigated.

Results: The percentages of patients very satisfied/satisfied and not really satisfied/dissatisfied with the treatment were 68% and 32%, respectively. Efficacy was rated as very good, good, moderate, and poor by 38%, 30%, 12%, and 20% of the cases, respectively. Efficacy was unrelated to gender and age and was highly correlated with pain score (P < 0.0001). In satisfied patients, the decrease in consumption of analgesics/non-steroidal anti-inflammatory drugs was >75% in 64% of the cases. Efficacy was significantly different with regard to imaging guidance. There was a statistically significant difference in efficacy and satisfaction between landmark-guided and imaging-guided injections (P = 0.02). The success rate was 2.3 times higher in the imaging-guided group than in the landmark-guided group. No significant difference was found between patients injected under fluoroscopy or ultrasound guidance, despite a trend favoring ultrasound (P = 0.09). Tolerability was rated as very good/good in 47 patients, moderate in two, and poor in one and was unrelated to the type of guidance.

Conclusion: This preliminary study suggests that the use of imaging guidance significantly optimizes the success rate of ankle viscosupplementation. No safety concern was observed.

Level of evidence: III.

Keywords: ankle; fluoroscopy; guidance; hyaluronic acid; osteoarthritis; ultrasonography; viscosupplementation.