Intrasurgical dignity assessment of hepatic tumors using semi-quantitative strain elastography and contrast-enhanced ultrasound for optimisation of liver tumor surgery

Clin Hemorheol Microcirc. 2016;64(4):735-745. doi: 10.3233/CH-168029.

Abstract

Objective: To evaluate the efficacy of strain elastography (SE) using semi-quantitative measurement methods compared to constrast enhanced ultrasound during liver tumor surgery (Io-CEUS) for dignity assessment of focal liver lesions(FLL).

Material and methods: Prospective data acquisition and retrospective analysis of US data of 100 patients (116 lesions) who underwent liver tumor surgery between 10/2010 and 03/2016. Retrospective reading of SE color patterns was performed establishing groups depending on dominant color (>50% blue = stiff, inhomogenous, >50% yellow/red/green = soft tissue). Semi-quantitative analysis was performed by Q-analysis based on a scale from 0 (soft) to 6 (stiff). 2 ROIs were placed centrally, 5 ROIs in the lesion's surrounding tissue. Io-CEUS was performed by bolus injection of 5-10 ml sulphurhexaflourid microbubbles evaluating wash-in- and -out- kinetics in arterial, portal venous and late phase. Histopathology after surgical resection served as goldstandard.

Results: 100 patients (m: 65, f: 35, mean age 60.5 years) with 116 liver lesions were included. Lesion's size ranged from 0.5 to 8.4 cm (mean 2.42 cm SD±1.44 cm). Postoperative histology showed 105 malignant and 11 benign lesions. Semi-quantitative analysis showed central indurations of >2.5 in 76/105 cases suggesting malignancy. 7 benign lesions displayed no central indurations correctly characterized benign by SE. ROC-analysis and Youden index showed a sensitivity of 72.4% and specificity of 63.6% assuming a cut-off of 2.5. Io-CEUS correctly characterized 103/105 as malignant. Sensitivity was 98%, specificity 72.7%.

Conclusion: Strain elastography is a valuable tool for non-invasive characterization of FLLs. Semi-quantitative intratumoral stiffness values of >2.5 suggested malignancy. However, sensitivity of Io-CEUS in detecting malignant lesions was higher compared to SE. In conclusion SE should be considered for routine use during intraoperative US in addition to Io-CEUS for optimization of curative liver surgery.

Keywords: CEUS; Ultrasound; elastography; strain elastography; surgery.

MeSH terms

  • Adult
  • Aged
  • Contrast Media / therapeutic use*
  • Elasticity Imaging Techniques / methods*
  • Female
  • Humans
  • Liver Neoplasms / diagnostic imaging
  • Liver Neoplasms / pathology
  • Liver Neoplasms / surgery*
  • Male
  • Middle Aged
  • Prospective Studies
  • Retrospective Studies
  • Ultrasonography / methods*

Substances

  • Contrast Media