Aortic and Hepatic Contrast Enhancement During Hepatic-Arterial and Portal Venous Phase Computed Tomography Scanning: Multivariate Linear Regression Analysis Using Age, Sex, Total Body Weight, Height, and Cardiac Output

J Comput Assist Tomogr. 2017 Mar/Apr;41(2):309-314. doi: 10.1097/RCT.0000000000000513.

Abstract

Objective: We evaluated the effect of the age, sex, total body weight (TBW), height (HT) and cardiac output (CO) of patients on aortic and hepatic contrast enhancement during hepatic-arterial phase (HAP) and portal venous phase (PVP) computed tomography (CT) scanning.

Methods: This prospective study received institutional review board approval; prior informed consent to participate was obtained from all 168 patients. All were examined using our routine protocol; the contrast material was 600 mg/kg iodine. Cardiac output was measured with a portable electrical velocimeter within 5 minutes of starting the CT scan. We calculated contrast enhancement (per gram of iodine: [INCREMENT]HU/gI) of the abdominal aorta during the HAP and of the liver parenchyma during the PVP. We performed univariate and multivariate linear regression analysis between all patient characteristics and the [INCREMENT]HU/gI of aortic- and liver parenchymal enhancement.

Results: Univariate linear regression analysis demonstrated statistically significant correlations between the [INCREMENT]HU/gI and the age, sex, TBW, HT, and CO (all P < 0.001). However, multivariate linear regression analysis showed that only the TBW and CO were of independent predictive value (P < 0.001). Also, only the CO was independently and negatively related to aortic enhancement during HAP and to liver parenchymal enhancement when the contrast material injection protocol was adjusted for the TBW (P < 0.001).

Conclusion: By multivariate linear regression analysis only the TBW and CO were significantly correlated with aortic and liver parenchymal enhancement; the age, sex, and HT were not. The CO was the only independent factor affecting aortic and liver parenchymal enhancement at hepatic CT when the protocol was adjusted for the TBW.

MeSH terms

  • Adult
  • Age Factors
  • Aged
  • Aged, 80 and over
  • Aorta, Abdominal / diagnostic imaging
  • Aorta, Abdominal / physiopathology
  • Body Height / physiology*
  • Body Weight / physiology*
  • Cardiac Output / physiology*
  • Contrast Media*
  • Female
  • Hepatic Artery / diagnostic imaging*
  • Hepatic Artery / physiopathology
  • Humans
  • Iohexol
  • Male
  • Middle Aged
  • Portal Vein / diagnostic imaging
  • Portal Vein / physiopathology
  • Prospective Studies
  • Radiographic Image Enhancement / methods*
  • Sex Factors
  • Tomography, X-Ray Computed / methods*

Substances

  • Contrast Media
  • Iohexol