Design and implementation of wireless dose logger network for radiological emergency decision support system

Rev Sci Instrum. 2016 Aug;87(8):085107. doi: 10.1063/1.4960403.

Abstract

A decision support system (DSS) is implemented in Radiological Safety Division, Indira Gandhi Centre for Atomic Research for providing guidance for emergency decision making in case of an inadvertent nuclear accident. Real time gamma dose rate measurement around the stack is used for estimating the radioactive release rate (source term) by using inverse calculation. Wireless gamma dose logging network is designed, implemented, and installed around the Madras Atomic Power Station reactor stack to continuously acquire the environmental gamma dose rate and the details are presented in the paper. The network uses XBee-Pro wireless modules and PSoC controller for wireless interfacing, and the data are logged at the base station. A LabView based program is developed to receive the data, display it on the Google Map, plot the data over the time scale, and register the data in a file to share with DSS software. The DSS at the base station evaluates the real time source term to assess radiation impact.

MeSH terms

  • Decision Making*
  • Gamma Rays*
  • Humans
  • Radiation Dosage*
  • Software*
  • Wireless Technology*