Elective or Emergency Use of Mechanical Circulatory Support Devices During Transcatheter Aortic Valve Replacement

J Interv Cardiol. 2016 Oct;29(5):513-522. doi: 10.1111/joic.12323. Epub 2016 Aug 22.

Abstract

Objective: Evaluate the use of mechanical circulatory support (MCS) devices in high-risk patients undergoing transcatheter aortic valve replacement (TAVR).

Background: The use of MCS devices in elderly patients with multiple comorbidities undergoing TAVR is underexplored.

Methods: All patients undergoing TAVR at a single tertiary academic center who required MCS during index procedure between 2008 and 2015 were included in a prospective database.

Results: MCS was used in 9.4% (54/577) of all TAVRs (n = 52 Edwards Sapien and n = 2 CoreValves) of which 68.5% (n = 37) were used as part of a planned strategy, and 31.5% (n = 17) were used in emergency "bail-out" situations. IABP was the most commonly used device (87%) followed by Impella and ECMO (6% each). Among the MCS group, 22% required cardiopulmonary resuscitation during the procedure (n = 4 elective [11%] vs. n = 8 emergent [47%]) and 15% upgrade to a second device (Impella or CPB after IABP; n = 5 elective [14%] vs. n = 3 emergent [18%]). Median duration of support was 1-day. Device related complications were low (4%). In-hospital mortality in this extremely high-risk population was 24% (13/54) (11% [4/37] for elective cases and 53% [9/17] for emergency cases). Cardiogenic shock (50%) was the most common cause of in-hospital death. Cumulative all-cause 1-year mortality was 35% (19/54) (19% 97/370 for elective and 71% [12/17] for emergency cases).

Conclusion: Emergent use of MCS during TAVR in extremely high-risk population is associated with high short and long-term mortality rates. Early identification of patients at risk for hemodynamic compromise may rationalize elective utilization of MCS during TAVR.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve Stenosis / diagnosis
  • Aortic Valve Stenosis / surgery*
  • Assisted Circulation* / instrumentation
  • Assisted Circulation* / methods
  • Assisted Circulation* / mortality
  • Cardiopulmonary Bypass* / instrumentation
  • Cardiopulmonary Bypass* / methods
  • Cardiopulmonary Bypass* / mortality
  • Elective Surgical Procedures / methods
  • Elective Surgical Procedures / statistics & numerical data*
  • Emergency Medical Services / methods
  • Emergency Medical Services / statistics & numerical data*
  • Female
  • Hospital Mortality
  • Humans
  • Male
  • Outcome and Process Assessment, Health Care
  • Prospective Studies
  • Severity of Illness Index
  • Survival Analysis
  • Transcatheter Aortic Valve Replacement* / adverse effects
  • Transcatheter Aortic Valve Replacement* / methods
  • United States / epidemiology