Comparison between two angular stable locking plates for medial opening-wedge high tibial osteotomy: Decisive wedge locking plate versus TomoFix™

J Orthop Sci. 2016 Nov;21(6):791-797. doi: 10.1016/j.jos.2016.07.019. Epub 2016 Aug 11.

Abstract

Background: An adequate stable fixation implant should be used for medial opening-wedge high tibial osteotomy (MOWHTO) to promote rapid bone healing without complications. This study compared the radiographic and clinical outcomes as well as plate-specific complications between two angular stable locking plates in patients following MOWHTO.

Method: This prospective study involved 97 patients (50 with DWL®, group I; 47 with TomoFix™, group II) undergoing MOWHTO for primary medial compartment osteoarthritis between 2010 and 2013. Clinical and radiographic evaluations were performed by using the HSS and WOMAC scores, and calculating mechanical femorotibial angle (mFTA), medial proximal tibial angle (MPTA), joint line convergence angle (JLCA), and posterior tibial slope (PTS) on radiographs both preoperatively and after 3 years.

Results: A statistically significant difference was observed for the MPTA at the last follow-up between the two groups (P = 0.033). Additionally, the last follow-up MPTA of group I was associated with the osteotomy technique (P = 0.004) and preoperative JLCA (P = 0.034) whereas the last follow-up MPTA of group II was associated with gender (P = 0.001) and BMI (P = 0.008). Furthermore, the results showed that group I had a higher rate of non-union (4%) compared to that in group II (0%).

Conclusion: Both locking plates are useful tools in the treatment of medial compartment knee osteoarthritis with varus deformity in young, active patients. However, under special consideration of the complication we found in present study, the TomoFix™ seems to be a better alternative in using the MOWHTO for highly demanding patients.

Publication types

  • Comparative Study

MeSH terms

  • Aged
  • Bone Plates*
  • Cohort Studies
  • Confidence Intervals
  • Equipment Design / methods*
  • Female
  • Follow-Up Studies
  • Humans
  • Joint Deformities, Acquired / diagnostic imaging
  • Joint Deformities, Acquired / surgery
  • Male
  • Middle Aged
  • Osteoarthritis, Knee / diagnostic imaging
  • Osteoarthritis, Knee / rehabilitation
  • Osteoarthritis, Knee / surgery*
  • Osteotomy / instrumentation*
  • Osteotomy / methods
  • Pain Measurement
  • Postoperative Care / methods
  • Prospective Studies
  • Radiography
  • Range of Motion, Articular / physiology*
  • Recovery of Function
  • Republic of Korea
  • Severity of Illness Index
  • Tibia / surgery*