Shaping Ability of Single-file Systems with Different Movements: A Micro-computed Tomographic Study

Iran Endod J. 2016 Summer;11(3):228-33. doi: 10.7508/iej.2016.03.016. Epub 2016 May 1.

Abstract

Introduction: This study aimed to perform a rigorous sample standardization and also evaluate the preparation of mesiobuccal (MB) root canals of maxillary molars with severe curvatures using two single-file engine-driven systems (WaveOne with reciprocating motion and OneShape with rotary movement), using micro-computed tomography (micro-CT).

Methods and materials: Ten MB roots with single canals were included, uniformly distributed into two groups (n=5). The samples were prepared with a WaveOne or OneShape files. The shaping ability and amount of canal transportation were assessed by a comparison of the pre- and post-instrumentation micro-CT scans. The Kolmogorov-Smirnov and t-tests were used for statistical analysis. The level of significance was set at 0.05.

Results: Instrumentation of canals increased their surface area and volume. Canal transportation occurred in coronal, middle and apical thirds and no statistical difference was observed between the two systems (P>0.05). In apical third, significant differences were found between groups in canal roundness (in 3 mm level) and perimeter (in 3 and 4 mm levels) (P<0.05).

Conclusion: The WaveOne and One Shape single-file systems were able to shape curved root canals, producing minor changes in the canal curvature.

Keywords: Micro-Computed Tomography; OneShape; Reciprocating Motion; Rotary System; WaveOne.