Moving Forward with Backward Compatibility: Translating Wrist Accelerometer Data

Med Sci Sports Exerc. 2016 Nov;48(11):2142-2149. doi: 10.1249/MSS.0000000000001015.

Abstract

Purpose: This study aimed to provide a means for calibrating raw acceleration data from wrist-worn accelerometers in relation to past estimates of children's moderate-to-vigorous physical activity (MVPA) from a range of cut points applied to hip-worn ActiGraph data.

Methods: This is a secondary analysis of three studies with concurrent 7-d accelerometer wear at the wrist (GENEActiv) and hip (ActiGraph) in 238 children age 9-12 yr. The time spent above acceleration (ENMO) thresholds of 100, 150, 200, 250, 300, 350, and 400 mg from wrist acceleration data (≤5-s epoch) was calculated for comparison with MVPA estimated from widely used children's hip-worn ActiGraph MVPA cut points (Freedson/Trost, 1100 counts per minute; Pate, 1680 counts per minute; Evenson, 2296 counts per minute; Puyau, 3200 counts per minute) with epochs of ≤5, 15, and 60 s.

Results: The optimal ENMO thresholds for alignment with MVPA estimates from ActiGraph cut points determined from 70% of the sample and cross validated with the remaining 30% were as follows: Freedson/Trost = ENMO 150+ mg, irrespective of ActiGraph epoch (intraclass correlation [ICC] ≥ 0.65); Pate = ENMO 200+ mg, irrespective of ActiGraph epoch (ICC ≥ 0.67); Evenson = ENMO 250+ mg for ≤5- and 15-s epochs (ICC ≥ 0.69) and ENMO 300+ mg for 60-s epochs (ICC = 0.73); Puyau = ENMO 300+ mg for ≤5-s epochs (ICC = 0.73), ENMO 350+ mg for 15-s epochs (ICC = 0.73), and ENMO 400+ mg for 60-s epochs (ICC = 0.65). Agreement was robust with cross-validation ICC = 0.62-0.71 and means within ∣7.8∣% ± 4.9% of MVPA estimates from ActiGraph cut points, except Puyau 60-s epochs (ICC = 0.42).

Conclusion: Incremental ENMO thresholds enable children's acceleration data measured at the wrist to be simply and directly compared, at a group level, with past estimates of MVPA from hip-worn ActiGraphs across a range of cut points.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Acceleration
  • Accelerometry / methods*
  • Child
  • Exercise / physiology*
  • Female
  • Hip
  • Humans
  • Male
  • Movement / physiology
  • Reproducibility of Results
  • Wrist