Feasibility of self-gated isotropic radial late-phase MR imaging of the liver

Eur Radiol. 2017 Mar;27(3):985-994. doi: 10.1007/s00330-016-4433-0. Epub 2016 Jun 8.

Abstract

Objective: To evaluate feasibility of a 3D-isotropic self-gated radial volumetric interpolated breath-hold examination (VIBE) for late-phase MRI of the liver.

Material and methods: 70 patients were included and underwent liver MRI at 1.5 T. Depending on the diagnosis, either Gd-EOB-DTPA (35 patients) or gadobutrol (35 patients) were administered. During late (gadobutrol) or hepatocyte-specific phase (Gd-EOB-DTPA), a radial prototype sequence was acquired and reconstructed using (1) self-gating with 40 % acceptance (rVIBE40); (2) with 100 % acceptance of the data (rVIBE100) and compared to Cartesian VIBE (cVIBE). Images were assessed qualitatively (image quality, lesion conspicuity, artefacts; 5-point Likert-scale: 5 = excellent; two independent readers) and quantitatively (coefficient-of-variation (CV); contrast-ratio) in axial and coronal reformations.

Results: In eight cases only rVIBE provided diagnostic image quality. Image quality of rVIBE40 was rated significantly superior (p < 0.05) in Gd-EOB-DTPA-enhanced and coronal reformatted examinations as compared to cVIBE. Lesion conspicuity was significantly improved (p < 0.05) in coronal reformatted Gd-EOB-DTPA-enhanced rVIBE40 in comparison to cVIBE. CV was higher in rVIBE40 as compared to rVIBE100/cVIBE (p < 0.01). Gadobutrol-enhanced rVIBE40 and cVIBE showed higher contrast-ratios than rVIBE100 (p < 0.001), whereas no differences were found in Gd-EOB-DTPA-enhanced examinations.

Conclusion: Self-gated 3D-isotropic rVIBE provides significantly superior image quality compared to cVIBE, especially in multiplanar reformatted and Gd-EOB-DTPA-enhanced examinations.

Key points: • Radial VIBE acquisition reduces motion artefacts. • Gd-EOB-DTPA-enhanced scans provide improved image quality. • Non-diagnostic liver MRI examinations may be reduced by radial k-spaces sampling.

Keywords: Artefacts; Gd-EOB-DTPA; Liver; Magnetic resonance imaging; Radial VIBE.

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Artifacts
  • Breath Holding
  • Contrast Media
  • Feasibility Studies
  • Female
  • Gadolinium DTPA
  • Hepatocytes / pathology
  • Humans
  • Image Enhancement / methods
  • Image Interpretation, Computer-Assisted / methods*
  • Imaging, Three-Dimensional / methods*
  • Liver / diagnostic imaging
  • Liver / pathology
  • Liver Diseases / diagnostic imaging*
  • Liver Diseases / pathology
  • Magnetic Resonance Imaging / methods*
  • Male
  • Middle Aged
  • Organometallic Compounds

Substances

  • Contrast Media
  • Organometallic Compounds
  • gadolinium ethoxybenzyl DTPA
  • gadobutrol
  • Gadolinium DTPA