Abstract

Aim: To assess the effect of 90°-oscillatory instrumentation with hand files on several morphological parameters (volume, surface area and uninstrumented surface) in C-shaped root canals after instrumentation using a single-file reciprocation system (Reciproc; VDW, Munich, Germany) and a Self-Adjusting File System (SAF; ReDent Nova, Ra'anana, Israel).

Methodology: Twenty mandibular second molars with C-shaped canals and C1 canal configurations were divided into two groups (n = 10) and instrumented with Reciproc and SAF instruments. A size 30 NiTi hand K-file attached to a 90°-oscillatory motion handpiece was used as final instrumentation in both groups. The specimens were scanned using micro-computed tomography after all procedures. Volume, surface area increase and uninstrumented root canal surface were analysed using CTAn software (Bruker-microCT, Kontich, Belgium). Also, the uninstrumented root canal surface was calculated for each canal third. All values were compared between groups using the Mann-Whitney test and within groups using the Wilcoxon's signed-rank test.

Results: Instrumentation with Reciproc significantly increased canal volume compared with instrumentation with SAF. Additionally, the canal volumes were significantly increased after 90°-oscillatory instrumentation (between and within group comparison; (P < 0.05)). Regarding the increase in surface area after all instrumentation protocols, statistical analysis only revealed significant differences in the within groups comparison (P < 0.05). Reciproc and SAF instrumentation yielded an uninstrumented root canal surface of 28% and 34%, respectively, which was not significantly different (P > 0.05). Final oscillatory instrumentation significantly reduced the uninstrumented root canal surface from 28% to 9% (Reciproc) and from 34% to 15% (SAF; P < 0.05). The apical and middle thirds exhibited larger uninstrumented root canal surfaces after the first instrumentation that was significantly reduced after oscillatory instrumentation (P < 0.05).

Conclusions: The Reciproc and SAF system were associated with similar morphological parameters after instrumentation of mandibular second molars with C-shaped canals except for a higher canal volume increase in the Reciproc group compared to the SAF. Furthermore, the final use of 90°-oscillatory instrumentation using NiTi hand files significantly decreased the uninstrumented canal walls that remained after Reciproc and SAF instrumentation.

Keywords: C-shaped root canal; Reciproc; Self-Adjusting File; micro-CT; nickel-titanium; root canal preparation.

MeSH terms

  • Dental Pulp Cavity / diagnostic imaging
  • Dental Pulp Cavity / surgery
  • Humans
  • Molar / diagnostic imaging
  • Molar / surgery
  • Nickel
  • Root Canal Therapy / instrumentation*
  • Root Canal Therapy / methods
  • Titanium
  • X-Ray Microtomography

Substances

  • titanium nickelide
  • Nickel
  • Titanium