Reliability, Validity, and Injury Predictive Value of the Functional Movement Screen: A Systematic Review and Meta-analysis

Am J Sports Med. 2017 Mar;45(3):725-732. doi: 10.1177/0363546516641937. Epub 2016 Jul 21.

Abstract

Background: The Functional Movement Screen (FMS) is utilized by professional and collegiate sports teams and the military for the prevention of musculoskeletal injuries.

Hypothesis: The FMS demonstrates good interrater and intrarater reliability and validity and has predictive value for musculoskeletal injuries.

Study design: Systematic review and meta-analysis.

Methods: A systematic review and meta-analysis were conducted using a computerized search of the electronic databases MEDLINE and ScienceDirect in adherence with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Extracted relevant data from each included study were recorded on a standardized form. The Cochran Q statistic was utilized to evaluate study heterogeneity. Pooled quantitative synthesis was performed to measure the intraclass correlation coefficient (ICC) for interrater and intrarater reliability, along with 95% CIs, and odds ratios with 95% CIs for the injury predictive value for a score of ≤14.

Results: Eleven studies for reliability, 5 studies for validity, and 9 studies for the injury predictive value were identified that met inclusion and exclusion criteria; of these, 6 studies for reliability and 9 studies for the injury predictive value were pooled for quantitative synthesis. The ICC for intrarater reliability was 0.81 (95% CI, 0.69-0.92) and for interrater reliability was 0.81 (95% CI, 0.70-0.92). The odds of sustaining an injury were 2.74 times with an FMS score of ≤14 (95% CI, 1.70-4.43). Studies for validity demonstrated flaws in both internal and external validity of the FMS.

Conclusion: The FMS has excellent interrater and intrarater reliability. Participants with composite scores of ≤14 had a significantly higher likelihood of an injury compared with those with higher scores, demonstrating the injury predictive value of the test. Significant concerns remain regarding the validity of the FMS.

Keywords: Functional Movement Screen; injury prevention.

Publication types

  • Meta-Analysis
  • Review
  • Systematic Review

MeSH terms

  • Athletic Injuries / diagnosis
  • Athletic Injuries / prevention & control*
  • Exercise Test / methods*
  • Humans
  • Movement
  • Musculoskeletal System / injuries*
  • Reproducibility of Results
  • Risk Assessment / methods*