Safety and Short-Term Complication Rates Using Single-Puncture T-Fastener Gastropexy

J Vasc Interv Radiol. 2016 Jun;27(6):898-904. doi: 10.1016/j.jvir.2016.02.033. Epub 2016 Apr 28.

Abstract

Purpose: To report a single operator's experience using a modified single-puncture gastrostomy technique deploying up to three nonabsorbable gastropexy anchors.

Materials and methods: A retrospective review of 69 consecutive patients undergoing gastrostomy, gastrojejunostomy, or jejunostomy tube insertion between March 2012 and January 2014 was performed. Technical success and 30-day local, major, and minor complication rates were assessed according to the Society of Interventional Radiology (SIR) Standards of Practice for Gastrointestinal Access. Procedure time was also recorded.

Results: Primary technical success of the procedure was 98.6% (68/69). In one patient, the procedure was aborted because the stomach could not be safely accessed. Major complications occurred in one of 69 (1.4%) patients, minor complications occurred in 10 of 69 (13%) patients, and local complications occurred in three of 69 (4.3%) patients. Local complications consisted of redness and mild tenderness at the enteric access site. Mean procedure time was 5 minutes (range, 3.1-36 min).

Conclusions: Single-puncture, multianchor gastrostomy is a feasible technique for radiologically guided enteric access tube insertion with technical success and complication rates similar to conventional gastrostomy techniques. This technique could be considered when expeditious performance of a procedure is required.

MeSH terms

  • Enteral Nutrition / adverse effects
  • Enteral Nutrition / instrumentation*
  • Enteral Nutrition / methods
  • Feasibility Studies
  • Gastropexy / adverse effects
  • Gastropexy / instrumentation*
  • Gastrostomy / adverse effects
  • Gastrostomy / instrumentation*
  • Humans
  • Jejunostomy / adverse effects
  • Jejunostomy / instrumentation*
  • Punctures
  • Radiography, Interventional
  • Retrospective Studies
  • Suture Techniques / adverse effects
  • Suture Techniques / instrumentation*
  • Time Factors
  • Treatment Outcome