The accuracy of axial length measurements in cases of macula-off retinal detachment

Can J Ophthalmol. 2016 Apr;51(2):108-12. doi: 10.1016/j.jcjo.2015.12.011.

Abstract

Objective: To assess the accuracy of axial length measurements in cases of macula-off retinal detachment using different methods (optical biometry, A-scan ultrasound, and combined applanation vector-A/B-scan biometry).

Methods: This prospective clinical study included 100 eyes of 100 patients who underwent vitrectomy alone or phacovitrectomy for macula-off retinal detachment. All patients included signed an informed consent. Preoperative examination of the patients included recording the axial length measurements using optical biometry, A-scan ultrasound, and combined applanation vector-A/B-scan biometry.

Results: The mean postoperative IOLMaster axial length after macular reattachment was 26.11 ± 2.91 mm. The mean preoperative IOLMaster axial length with macula-off was 25.32 ± 2.72 mm. The mean preoperative A-scan axial length with macula-off was 25.29 ± 2.80 mm. The mean preoperative vector-A/B-scan axial length with macula-off was 26.03 ± 2.90 mm. The preoperative vector-A/B-scan mean absolute error was 0.59 ± 0.48 D (range, 0.10-2.25 D).

Conclusions: Regular methods (optical biometry and A-scan biometry) of measuring the axial length in cases with a detached macula proved to be variable and less accurate. The vector-A/B-scan offered good measurements of the actual axial length in the patients. This was reflected on more accurate postoperative refractive outcome.

MeSH terms

  • Adult
  • Aged
  • Axial Length, Eye*
  • Biometry / methods*
  • Diagnostic Techniques, Ophthalmological*
  • Female
  • Humans
  • Macula Lutea*
  • Male
  • Middle Aged
  • Phacoemulsification
  • Prospective Studies
  • Reproducibility of Results
  • Retinal Detachment / complications*
  • Retinal Detachment / surgery
  • Visual Acuity
  • Vitrectomy
  • Young Adult