Effects of ultrasound on ovulation in the mouse

Gamete Res. 1989 Mar;22(3):333-8. doi: 10.1002/mrd.1120220310.

Abstract

In vitro fertilization and embryo transfer (IVF-ET) programs use ultrasound extensively for monitoring the growth of ovarian follicles and, subsequently, for confirming the presence of a fetal sac. There have been few reports of the effects of ultrasound on ovulation rates in mammals, and we report here that following exposure to continuous wave ultrasound at a spatial average intensity of 3.0 W/cm2 for five minutes, ovulation rates measured 10 days later were significantly reduced in mice. When temperature elevation of the exposed ovary was measured with a thermocouple, hyperthermia correlated with reduction in ovulation.

Publication types

  • Research Support, U.S. Gov't, P.H.S.

MeSH terms

  • Animals
  • Cell Count
  • Female
  • Mice
  • Oocytes / cytology
  • Ovulation*
  • Statistics as Topic
  • Ultrasonics*