Effect of patent ductus arteriosus and patent foramen ovale on left ventricular stroke volume measurement by electrical velocimetry in comparison to transthoracic echocardiography in neonates

J Clin Monit Comput. 2017 Jun;31(3):589-598. doi: 10.1007/s10877-016-9878-9. Epub 2016 Apr 12.

Abstract

This prospective single-center observational study compared impedance cardiography [electrical velocimetry (EV)] with transthoracic echocardiography (TTE, based on trans-aortic flow) and analyzed the influence of physiological shunts, such as patent ductus arteriosus (PDA) or patent foramen ovale (PFO), on measurement accuracy. Two hundred and ninety-one triplicate simultaneous paired left ventricular stroke volume (LVSV) measurements by EV (LVSVEV) and TTE (LVSVTTE) in 99 spontaneously breathing neonates (mean weight 3270 g; range 1227-4600 g) were included. For the whole cohort, the mean absolute LVSVEV was 5.5 mL, mean LVSVTTE was 4.9 mL, resulting in an absolute Bland-Altman bias of -0.7 mL (limits of agreement LOA -3.0 to 1.7 mL), relative bias -12.8 %; mean percentage error MPE 44.9 %; true precision TPEV 33.4 % (n = 99 aggregated data points). In neonates without shunts (n = 32): mean LVSVEV 5.0 mL, mean LVSVTTE 4.6 mL, Bland-Altman bias -0.4 mL (LOA -2.8 to 2.0 mL), relative bias -8.2 %; MPE 50.7 %; TPEV 40.9 %. In neonates with shunts (PDA and/or PFO; n = 67): mean LVSVEV 5.8 mL, mean LVSVTTE 5.0 mL, bias -0.8 mL (LOA -3.1 to 1.5 mL), relative bias -14.8 %, MPE 41.9 %, TPEV 29.3 %. Accuracy was affected by PDA and/or PFO, with a significant increase in the relative difference in LVSVEV versus LVSVTTE: Subjects without shunts -2.9 % (n = 91), PFO alone -9.6 % (n = 125), PDA alone -14.0 % (n = 12), and PDA and PFO -18.5 % (n = 63). Physiological shunts (PDA and/or PFO) in neonates affect measurement accuracy and cause overestimation of LVSVEV compared with LVSVTTE.

Keywords: Echocardiography; Impedance cardiography; Neonate; Patent ductus arteriosus; Patent foramen ovale; Stroke volume.

Publication types

  • Comparative Study
  • Observational Study

MeSH terms

  • Cardiography, Impedance / methods*
  • Ductus Arteriosus, Patent / complications
  • Ductus Arteriosus, Patent / diagnosis*
  • Ductus Arteriosus, Patent / physiopathology
  • Female
  • Foramen Ovale, Patent / complications
  • Foramen Ovale, Patent / diagnosis*
  • Foramen Ovale, Patent / physiopathology
  • Humans
  • Infant, Newborn
  • Male
  • Reproducibility of Results
  • Rheology / methods
  • Sensitivity and Specificity
  • Stroke Volume*
  • Ventricular Dysfunction, Left / diagnosis*
  • Ventricular Dysfunction, Left / etiology
  • Ventricular Dysfunction, Left / physiopathology