A 64 year-old male, was diagnosed with obstructive jaundice due to a well-differentiated pancreatic neuroendocrine tumor with liver metastases. The patient underwent endoscopic placement of covered self-expanding biliary stent (10x60 mm, Hanaro) by ERCP. He was admitted with cholangitis one year later. The following ERCP revealed a fractured stent with loss of the distal end (duodenal) and partial migration of the remaining stent to the common bile duct. The fragmented stent was removed from the common bile duct and a new, similar one was inserted. Four months later the patient was admitted with cholangitis. A new ERCP was done and biliary stent was also fragmented. It was removed and an uncovered stent (Wallflex) was inserted.